ArticleWorld journal of clinical cases2025
Retrograde approach of Angiojet catheter for the acute occlusion of aortoiliac artery stent: A case report.
Article in World journal of clinical cases, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAortoiliac artery stenting has been accepted as the preferred option for the treatment of aortoiliac artery disease because of lower morbidity and mortality compared with bypass surgery. However, acute stent occlusion is a troublesome complication due to the need for open surgery or the risk of distal embolization. Herein, we reported a novel approach to treat the acute thrombotic occlusion of an aortoiliac stent using both hemolytic and conventional mechanical thrombectomy coupled with a large diameter sheath. CASE SUMMARY: A 64-year-old male patient presented with severe claudication of the right leg. The patient's history included multiple prior interventions for aortoiliac lesions. The preoperative computed tomography (CT) imaging showed a thrombotic occlusion of right aortoiliac stenting. An Angiojet Omni thrombectomy catheter (Boston Scientific, Marlborough, MA, United States) was used to remove the thrombus in a retrograde fashion after the successful placement of the large-diameter sheath in the right common femoral artery for prevention of distal embolization. The remnant organized thrombus was removed with an over-the-wire Fogarty catheter (Edwards Lifesciences, Irvine, CA, United States). Completion angiogram and postoperative CT imaging demonstrated complete removal of thrombus and no evidence of distal embolization.
conclusionThis novel approach provides successful management of acute thrombotic occlusion of aortoiliac stent without distal embolization.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.