Evidence map›Paper›PMID 40821282›Full record

ArticleCureus2025

Context-Aware Retrieval-Augmented Generation for Artificial Intelligence in Urology.

Aadhitya Sriram, Maheswaran N, Bose Sundan, Sriram Krishnamoorthy

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. LabSage: Structural-Semantic Decoupling for Enhanced Retrieval-Augmented Generation in Clinical Laboratories.AMIA Joint Summits on Translational Science proceedings. AMIA Joint Summits on Translational Science · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Aadhitya SriramDepartment of Computer Science and Engineering, College of Engineering, Guindy, Anna University, Chennai, IND.
Maheswaran NDepartment of Computing Technologies, SRM Institute of Science and Technology, Chennai, IND.
Bose SundanDepartment of Computer Science and Engineering, College of Engineering, Guindy, Anna University, Chennai, IND.
Sriram KrishnamoorthyDepartment of Urology, Sri Ramachandra Institute of Higher Education and Research, Chennai, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Artificial intelligence (AI) is increasingly being used in healthcare, particularly for interpreting complex medical queries. However, conventional AI models often generate inaccurate or irrelevant responses that are commonly termed hallucinations, which may compromise patient safety. To address this, our study introduces a modified retrieval-augmented generation (RAG) framework tailored for the urology domain to enhance contextual relevance and accuracy in AI-generated responses. Methodology We developed a context-aware RAG system integrating PubMedBERT embeddings for encoding and retrieving urological literature stored in a Pinecone vector database. The system uses named entity recognition for domain-specific query filtering and incorporates dynamic memory to retain contextual flow during interactions. Response generation is powered by the LLaMA3-8B model via LangChain. A custom dataset of urology-related queries was used for evaluation, with a large language model-based scoring using the Deepseek-R1 model. Results The proposed framework demonstrated a significant reduction in hallucinations, with responses being more contextually relevant and evidence-based. Compared to baseline models, our system achieved an 89% performance improvement in generating medically appropriate answers. Integration of memory modules and named entity filtering further improved precision and reliability. Conclusions Our RAG-enhanced system shows strong potential for clinical use by producing trustworthy, context-aware responses in urology. It addresses key challenges in medical AI, including hallucination mitigation and domain relevance. Future work will focus on reducing inference latency and improving automated validation without manual oversight.

Indexed as

artificial intelligencecontext awarenesshallucinations in aimedical airetrieval-augmented generationurology

Identifiers

PMID40821282
PMCPMC12357645

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.