Evidence map›Paper›PMID 40820637›Full record

ArticleTransfusion2025

Quality control of intraoperative autologous blood salvage in cardiac surgery.

Sergio Domingos Vieira, Fernanda da Cunha Vieira Perini, Leandro Felipe Figueiredo Dalmazzo, Fabiana Akil, Pablo Raphael Gomiero Alves, Erika Abdon Fiquene Oliveira, Marcello Augusto Cesar, Tatiana Covas Pereira, Claudia Monteiro, Mara Cabral Moraes and 2 more

Abstract readMulticenter Study
In one paragraph

Article in Transfusion, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Sergio Domingos VieiraBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Fernanda da Cunha Vieira PeriniBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Leandro Felipe Figueiredo DalmazzoBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.ORCID https://orcid.org/0000-0002-9617-582X
Fabiana AkilBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Pablo Raphael Gomiero AlvesBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Erika Abdon Fiquene OliveiraBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Marcello Augusto CesarBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Tatiana Covas PereiraBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Claudia MonteiroBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Mara Cabral MoraesBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Katia Beatrice Lima BurattaBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.
Neila Jones MoitinhoBlood Bank, Grupo Gestor de Serviços de Hemoterapia-Grupo GSH, São Paulo, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe management of intraoperative autologous blood salvage (ABS) quality is essential to ensure safety and outcomes; although publications on this subject are scarce. We evaluated a standardized program of ABS quality control for cardiac and evaluated surgery predictors of mortality in this population.

methodsData from a multicenter retrospective study conducted in 27 institutions from January 2021 to December 2023 were analyzed. The quality control of washed autologous red blood cell concentrates that were recovered and reinfused into the patients was assessed directly from the reinfusion bag. Main quality indicators were hematocrit between 50% and 75%; hemolysis level <0.8%; and residual protein <0.5 g/u.

resultsA total of 424 patients and 225,814 mL of intraoperatively recovered washed autologous red blood cells were included, corresponding to 576.6 autologous units. We obtained compliant results in 94.6% for hematocrit, 98.3% for hemolysis levels, and 98.4% for residual protein. A total of 36 (8%) altered results were observed, with most cases (23% or 5.4%) related to hematocrit. Patients requiring homologous blood components were younger (p = .006), had lower body weights (congenital heart disease), were female (p <.001), had lower preoperative hematocrit and hemoglobin levels (p <.001), and experienced more intraoperative or perioperative complications (p <.05). The multivariable model yielded significant results for preoperative hemoglobin, hematocrit quality control, intrahospital complications, and blood units transfused.

conclusionABS is essential for the blood conservation program in cardiac surgery. Preoperative anemia, altered quality control, the need for homologous blood transfusion, and the occurrence of clinical and surgical complications impact patient outcomes.

Indexed as

Blood Transfusion, AutologousCardiac Surgical ProceduresOperative Blood SalvageAdultAgedFemaleHematocritHumansMaleMiddle AgedQuality ControlRetrospective Studiesblood transfusion, autologouscardiac surgical proceduresoperative blood salvagequality control

Identifiers

PMID40820637
PMCPMC12531945

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.