ArticleBMJ paediatrics open2025
Implementation of a brief training programme to reduce mask leak with a respiratory function monitor.
Article in BMJ paediatrics open, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Respiratory function monitors (RFMs) can provide real-time data including expiratory tidal volumes and interface leak during delivery room (DR) neonatal resuscitation. However, concerns have been raised within previous randomised controlled trials and systematic reviews that effectuating RFMs routinely for DR resuscitation is limited by lack of comprehensive staff training. The International Liaison Committee on Resuscitation have also recently declared a knowledge gap in terms of the training required to be competent in utilising an RFM during neonatal resuscitation. We conducted an experiment with thirteen medical students who had no prior resuscitation experience to see if visual feedback from an RFM could improve mask leak when ventilating an extremely preterm manikin. Following a brief training session with hands-on practice, 260 breaths were analysed and median mask leak improved from 6% (IQR 1-6%) during the first breath to 0% (IQR 0-1%) by the twentieth and final breath. The median expiratory tidal volume was 3.6 mL (IQR 3.4-3.8 mL) and remained stable. This manikin experiment has demonstrated that even a short and experiential training session with an RFM for participants with no prior resuscitation training can be effective in reducing mask leak.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.