Evidence map›Paper›PMID 40817420›Full record

ArticleJournal of applied clinical medical physics2025

Application of a model-based water-equivalent EPID image conversion algorithm for linac beam QA.

Ivan Kutuzov, Boyd McCurdy

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ivan KutuzovDepartment of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba, Canada.ORCID https://orcid.org/0009-0008-2539-1251
Boyd McCurdyDepartment of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe nonwater-equivalent energy response of electronic portal imaging devices (EPIDs) is a major obstacle to using them for linear accelerator (linac) beam parameter verification. In this study, we propose an EPID-based machine quality assurance (QA) application that uses a model-based radiation transport algorithm to convert EPID-measured images into water-equivalent dose distributions that can be used to assess beam flatness and symmetry.

methodsAn in-house developed, model-based radiation transport algorithm was used to estimate the incident beam fluence from measured EPID images and convert it into either 3D dose distributions in a virtual water tank or 2D water-equivalent dose distributions in a virtual ion chamber array. The conversion algorithm was validated using independent measurements in a scanning water tank and a reference ion chamber array under symmetric and also intentionally detuned (i.e., asymmetric) beam conditions.

resultsFor symmetric fields, EPID-reconstructed percentage depth dose distributions (PDDs) agreed with water tank measurements to within 1% beyond the first 10 mm of depth. Beam profile comparisons showed differences within 1% in low dose-gradient regions. For all symmetric and intentionally asymmetric fields, beam flatness and symmetry derived from reconstructed images agreed with reference measurements to within 0.2% and 0.3%, respectively. The model demonstrated high sensitivity to the controlled beam asymmetries and steering distortions, with EPID-reconstructed metrics closely matching reference water-equivalent measurements and significantly outperforming metrics derived from raw EPID images.

conclusionsThe proposed model-based algorithm enables accurate conversion of EPID images into water-equivalent dose distributions, facilitating accurate determination of beam flatness and symmetry. This application addresses some limitations of the previously proposed EPID-based linac QA techniques, which are limited to nonwater-equivalent constancy checks, and supports the use of EPIDs as robust dosimetry tools for linac radiation beam parameter verification.

Indexed as

AlgorithmsImage Processing, Computer-AssistedParticle AcceleratorsPhantoms, ImagingQuality Assurance, Health CareRadiometryRadiotherapy Planning, Computer-AssistedWaterHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedWaterEPIDEPID dosimetrylinac QAmachine QAwater‐equivalent EPID

Identifiers

PMID40817420
PMCPMC12356691

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.