ArticleJournal of applied clinical medical physics2025

A novel Cherenkov radiation removal method for plastic scintillator detectors in a 0.35 T MR-Linac.

Mateb Al Khalifa, Tianjun Ma, Haya Aljuaid, Siyong Kim, William Y Song

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mateb Al KhalifaDepartment of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.ORCID https://orcid.org/0000-0003-0627-8903
Tianjun MaDepartment of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Haya AljuaidDepartment of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.ORCID https://orcid.org/0009-0002-5650-3611
Siyong KimDepartment of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.ORCID https://orcid.org/0000-0002-9173-7141
William Y SongDepartment of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.ORCID https://orcid.org/0009-0003-3196-2368

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study evaluates methods for removing Cherenkov radiation (CR) from plastic scintillation detectors (PSDs), focusing on constraints specific to a 0.35 T MR-Linac system.

methodsFive CR-removal methods were examined: cross calibration, fiber alone, multiloop, collimator rotation, and couch rotation. The first three (cross calibration, fiber alone, and multiloop) were tested on a 0.35 T MR-Linac (ViewRay Inc., USA) using the BluePhysics PSD (Blue Physics LLC, USA). These methods do not require collimator or couch rotation. The remaining two methods (collimator rotation and couch rotation) were tested on a Varian TrueBeam (Varian Medical Systems, USA) for comparison. Measurements were performed under various setup configurations, and Cherenkov radiation extraction (CRE) values were calculated to determine each method's effectiveness.

resultsThe multiloop approach yielded a CRE of 0.7288, making it the most practical and robust for MR-Linac constraints because it requires neither collimator nor couch rotation. The cross calibration and fiber alone methods produced CRE values of 0.7318 and 0.7569, respectively. Collimator rotation gave 0.7255, comparable to multiloop. In contrast, couch rotation resulted in 0.7489 but exhibited more variability, suggesting lower reliability.

conclusionThe multiloop method emerged as the most practical and robust technique for CR removal in 0.35 T MR-Linac systems. Its simplicity and compatibility with MR-Linac design constraints make it a highly effective approach for CR removal in PSD-based radiotherapy applications.

Indexed as

Magnetic Resonance ImagingParticle AcceleratorsPhantoms, ImagingPlasticsRadiotherapy Planning, Computer-AssistedScintillation CountingCalibrationHumansPlasticsCherenkov radiationMR‐Linacplastic scintillation detectorsQAsmall field dosimetry

Identifiers

PMID40817237
PMCPMC12356693

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.