ArticleEuropean radiology experimental2025
Photon-counting CT in maxillofacial and temporal bone CT-a comparative analysis of image quality and dose with high-end energy-integrating CT systems.
Article in European radiology experimental, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Photon-counting detector computed tomography for temporal bone: does higher resolution matter?Current opinion in otolaryngology & head and neck surgery · 2026Review
- Next-gen paediatric imaging: ultra-low dose chest photon-counting CT approaching chest radiograph doses.European radiology experimental · 2026Article
- The cochlear morphometry compendium: High-resolution synchrotron measurements and normative reference values.Journal of anatomy · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThis experimental study aimed to compare the image quality of maxillofacial and temporal bone imaging using different radiation dose settings on current high-end CT systems: photon-counting detector CT (PCDCT), dual-source energy-integrating detector CT (DECT), and dual-layer spectral detector CT (SDCT). MATERIALS AND
methodsCT scans of a cadaveric human specimen were investigated. Temporal bone imaging was performed with the following parameters: 120 kV and A (high-dose): 140-100 mAs; B (middle-dose): 90-60 mAs; C (low-dose): 50-25 mAs; D (ultra-low-dose): 20-10 mAs. Similarly, for maxillofacial CT: 100 kV and A: 100-80 mAs; B: 70-50 mAs; C: 40-25 mAs; D: 20-10 mAs. Region of interest (ROI)-based noise, SNR, and CNR ratios were calculated for objective assessment of image quality. Subjectively, image quality (IQ) of important anatomic landmarks was assessed using a Likert grading scale from 1 (non-diagnostic) to 5 (excellent).
resultsFor temporal bone, PCDCT provided excellent-to-good IQ up to low-dose scans for all anatomical landmarks, which was superior to SDCT (excellent-to-sufficient), followed by DECT (good-to-poor): e.g., for C: 4.3 ± 0.5 versus 3.7 ± 0.6 versus 2.9 ± 0.6, p < 0.001. PCDCT had significantly better IQ compared to SDCT in ultra-low-dose settings (D: 3.9 ± 0.4 versus 2.8 ± 0.4, p < 0.001). For maxillofacial CT, no significant differences in IQ were found between all CT systems using high- and middle-dose scans, e.g., B: 3.9 ± 0.5 versus 3.8 ± 0.7 versus 3.8 ± 0.4 (p = 0.81). In low- and ultra-low-dose settings, IQ was similar by PCDCT and SDCT (C: p = 0.17; D: p = 0.99) and superior to that of DECT (C: p < 0.05).
conclusionPCDCT offers excellent image quality for temporal bone and maxillofacial CT even at ultra-low doses; results were, in some cases, superior to SDCT and DECT. RELEVANCE STATEMENT: As PCDCT outperformed modern DECT and SDCT in assessment of maxillofacial and temporal bone CT for image quality and radiation dose, our study suggests that the implementation of PCDCT will improve image quality while reducing radiation exposure in general population. KEY POINTS: This work compares the quality of maxillofacial and temporal bone imaging in PCDCT, DECT, and SDCT. Scans of a cadaveric human specimen were investigated using different radiation doses. PCDCT offers excellent image quality for temporal bone and maxillofacial CT. PCDCT, SDCT, and DECT all showed good image quality overall.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials