Evidence map›Paper›PMID 40814052›Full record

ArticleBMC oral health2025

Finite element analysis of the impact of different traction anchorage locations on maxillary molar distalization with clear aligners and implant screws.

Xiangyu Ma, Chunmiao Jiang, Jie Zhang, Hong Ding, Qianwen Zhang, Zhijie Yang, Tianwei Shang, Cunhui Fan

Abstract read
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. [Comparative study on the clinical performance of concealable traction hook spherical buccal tubes versus conventional rectangular buccal tubes].Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2026
    Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xiangyu MaSchool of Stomatology, Qingdao University, Qingdao, 266023, China.
Chunmiao JiangDepartment of Orthodontics, The Affiliated Hospital of Qingdao University, Qingdao, 266003, China.
Jie ZhangDepartment of Orthodontics, The Affiliated Hospital of Qingdao University, Qingdao, 266003, China.
Hong DingDepartment of Orthodontics, The Affiliated Hospital of Qingdao University, Qingdao, 266003, China.
Qianwen ZhangSchool of Stomatology, Qingdao University, Qingdao, 266023, China.
Zhijie YangSchool of Stomatology, Qingdao University, Qingdao, 266023, China.
Tianwei ShangSchool of Stomatology, Qingdao University, Qingdao, 266023, China.
Cunhui FanDepartment of Orthodontics, The Affiliated Hospital of Qingdao University, Qingdao, 266003, China. kysfch@126.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aims to evaluate the impact of different implant screw insertion sites and traction point combinations of clear aligners on anchorage control during maxillary molar distalization using a three-dimensional finite element analysis.

methodsA finite element model was developed with the second maxillary molar distalized by 2 mm, followed by the distalization of the first maxillary molar by 0.25 mm. The control group, which did not include implant screws, was compared to two experimental groups (A and B), defined by the implant screw insertion sites: between the second premolar and first molar (Group A), and between the first and second molars (Group B). Each traction group was further subdivided (A1, A2, B1, B2) based on the clear aligner traction point location, which was either at the canine or first premolar. Three different force levels (100 g, 150 g, and 200 g) were applied to each group. The primary outcomes assessed were the distalization rate of the maxillary first molar, the three-dimensional displacement of each tooth, and the equivalent stress in the periodontal ligament under various conditions.

resultsAll conditions resulted in distal movement of the first molar and mesial displacement of the remaining teeth.The control group achieved a first molar distalization rate of 58.76%. Among the traction groups, Group B2 demonstrated the highest distalization rate (59.44%) at 200 g. When compared to the other traction groups, B2 exhibited the greatest distalization of the first molar, while minimizing labial displacement of the incisors. However, this configuration also resulted in increased labial displacement of the canine.

conclusionThe results suggest that implant screws placed between the first and second molars, combined with traction points at the first premolar using clear aligners, offer superior molar distalization efficiency and improved control over incisor anchorage during maxillary molar distalization.

Indexed as

Bone ScrewsDental ImplantsFinite Element AnalysisMolarOrthodontic Anchorage ProceduresOrthodontic Appliance DesignTooth Movement TechniquesBicuspidBiomechanical PhenomenaCuspidDental Stress AnalysisHumansImaging, Three-DimensionalMaxillaPeriodontal LigamentStress, MechanicalDental ImplantsClear alignersFinite element analysisMiniscrew anchorageMolar distalization

Identifiers

PMID40814052
PMCPMC12351846

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.