Evidence map›Paper›PMID 40809984›Full record

ArticleBiomedical optics express2025

Experimental and numerical investigation of wavelength and resolution dependency of dynamic optical coherence tomography signals.

Shumpei Fujimura, Ibrahim Abd El-Sadek, Rion Morishita, Shuichi Makita, Atsuko Furukawa, Pradipta Mukherjee, Yiheng Lim, Lida Zhu, Yunake Feng, Thitiya Seesan and 2 more

Abstract read
In one paragraph

Article in Biomedical optics express, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Shumpei FujimuraComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Ibrahim Abd El-SadekComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.ORCID https://orcid.org/0000-0002-0674-169X
Rion MorishitaComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.ORCID https://orcid.org/0000-0002-5396-0617
Shuichi MakitaComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.ORCID https://orcid.org/0000-0002-6614-3640
Atsuko FurukawaClinical Research and Regional Innovation, Faculty of Medicine, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Pradipta MukherjeeComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.ORCID https://orcid.org/0000-0002-5752-9963
Yiheng LimComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.ORCID https://orcid.org/0000-0002-0777-555X
Lida ZhuComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.ORCID https://orcid.org/0000-0001-8669-4012
Yunake FengComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Thitiya SeesanComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Satoshi MatsusakaClinical Research and Regional Innovation, Faculty of Medicine, University of Tsukuba, Tsukuba, Ibaraki, Japan.
Yoshiaki YasunoComputational Optics Group, University of Tsukuba, Tsukuba, Ibaraki, Japan.ORCID https://orcid.org/0000-0003-1645-7948

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The wavelength and system-resolution dependencies of dynamic optical coherence tomography (DOCT) are investigated experimentally and numerically. Experimental investigations demonstrate significant wavelength dependency for the DOCT values but no marked resolution dependency. Numerical simulations were performed using diffusion, random-ballistic motion, and mono-directional flow-based motion models. Diffusion and random-ballistic motion-based simulations show significant wavelength dependency. Additionally, these simulations revealed a small but certain resolution dependency. Mono-directional flow simulations did not show wavelength dependency but did demonstrate resolution dependency. The DOCT value is sensitive to both tissue dynamics and the OCT system specification. These effects should be considered when interpreting DOCT images.

Identifiers

PMID40809984
PMCPMC12339306

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.