ArticleBiomedical optics express2025
Article in Biomedical optics express, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Evaluating the applicability of computational super-resolution techniques for harmonic generation microscopy.Scientific reports · 2026Article
- Erratum:Biomedical optics express · 2025Article
Corrections and comments
- Erratum issuedErratum:2025
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The human cornea is a highly organized tissue, which comprises hundreds of 1-3 µm thick stacked collagen lamellae. However, this microstructure is poorly characterized and requires further investigation. Polarization-resolved second harmonic generation (pSHG) microscopy is a powerful technique for this purpose because of its specificity for collagen and its sensitivity to its orientation. However, pSHG is prone to spatial resolution degradation with depth unless the immersion refractive index is matched to that of the sample, which is critical for corneas that are approximately 600 µm thick. In the absence of experimental data on the refractive index along the entire cornea, we propose a measurement method that applies to the entire cornea directly under the microscope objective. We then use an iodixanol solution to match the refractive index of the immersion medium to that of the cornea. Finally, we carefully characterize the pSHG orientation data obtained under these optimal conditions, and we show that they provide a better resolution along the entire thickness of the cornea and a better determination of the lamellae orientation.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.