ArticleJournal of thoracic disease2025
Manual slow firing mode of Signia™ Stapling System can achieve less staple line bleeding from pulmonary artery.
Article in Journal of thoracic disease, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Article
- Evaluation of the utility of slow mode for pulmonary vessel resection using a surgical stapler in anatomical pulmonary resection: a prospective randomized controlled trial protocol.Journal of thoracic disease · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Staple line (SL) bleeding from the pulmonary artery (PA) can interfere with subsequent surgical procedures and prolong operative time. SL bleeding is associated with staple malformation and vessel wall damage. The manual slow firing mode (MSFM) is a function of Covidien's powered stapler Signia™, which performs firing at a continuous slow speed, whereas the conventional stapling mode adjusts the stapling speed based on tissue thickness. The slow-speed stapling of the PAs may help prevent staple malformation and vessel wall damage, thereby contributing to the reduction in SL bleeding. This study aimed to evaluate the effects of MSFM on PA dissection. Methods: Of the 433 anatomical lung resections performed at our institution between November 2020 and November 2024, patients who underwent anatomical lung resection using the Signia™ small diameter reload with a gray 30 mm cartridge were included. PA dissection was classified into the conventional normal mode (NM) and MSFM; the frequency of SL bleeding was evaluated using each mode. SL bleeding was defined as bleeding/oozing that persisted for at least 15 s without any intervention or after the required compression for ≥5 s. We also evaluated SL bleeding in small-diameter (<7 mm), which could be safely dissected using an energy device, and in large-diameter vessels (≥7 mm). Results: Among the 82 patients, the total number of dissected pulmonary arteries was 84 and 87 in the NM and MSFM groups, respectively. The median (range) diameter was 6.6 (range, 2.1-14.1) mm in the NM and 6.3 (range, 2.3-14.2) mm in the MSFM groups (P=0.59). SL bleeding was significantly lower in the MSFM group [11.5% (10/87)] than in the NM group [26.2% (22/84)] (P=0.01). SL bleeding in the small vessels was 19.1% (9/47) in the NM group and 10.2% (5/49) in the MSFM group, with no significant difference (P=0.26). In contrast, for large vessels, SL bleeding was significantly lower in the MSFM group [13.2% (5/38)] compared with the NM group [35.1% (13/37)] (P=0.03). Conclusions: MSFM could reduce SL bleeding from large-diameter PAs and might contribute to improved intraoperative safety.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.