Evidence map›Paper›PMID 40807827›Full record

ArticleSensors (Basel, Switzerland)2025

Enhanced Calibration Method for Robotic Flexible 3D Scanning System.

Zhilong Zhou, Jinyong Shangguan, Xuemei Sun, Yunlong Liu, Xu Zhang, Dengbo Zhang, Haoran Liu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. An Open-Source, Low-Cost Solution for 3D Scanning.Sensors (Basel, Switzerland) · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhilong ZhouCollege of Mechanical and Vehicle Engineering, Linyi University, Linyi 276012, China.ORCID 0009-0004-7434-1606
Jinyong ShangguanCollege of Mechanical and Vehicle Engineering, Linyi University, Linyi 276012, China.
Xuemei SunCollege of Mechanical and Vehicle Engineering, Linyi University, Linyi 276012, China.
Yunlong LiuCollege of Mechanical and Vehicle Engineering, Linyi University, Linyi 276012, China.
Xu ZhangCollege of Mechanical and Vehicle Engineering, Linyi University, Linyi 276012, China.
Dengbo ZhangCollege of Mechanical and Vehicle Engineering, Linyi University, Linyi 276012, China.
Haoran LiuCollege of Mechanical and Vehicle Engineering, Linyi University, Linyi 276012, China.

Funding

Natural Science Foundation of Shandong Province ZR2024QE152Natural Science Foundation of Shandong Province ZR2024QE386Science and Technology Smes Innovation Ability Improvement Project of Shandong Province 2023TSGC0459Science and Technology Smes Innovation Ability Improvement Project of Shandong Province 2024TSGC0829Scientific Research of Linyi University Z6124007Youth Entrepreneurship Technology Support Program for Higher Education Institutions of Shandong Province 2023KJ215
6 · The paper itself

Abstract

Large-sized components with numerous small key local features are essential in advanced manufacturing. Achieving high-precision quality control necessitates accurate and highly efficient three-dimensional (3D) measurement techniques. A flexible measurement system integrating a fringe-projection-based 3D scanner with an industrial robot is developed to enable the rapid measurement of large object surfaces. To enhance overall measurement accuracy, we propose an enhanced calibration method utilizing a multidimensional ball-based calibrator to simultaneously calibrate for hand-eye transformation and robot kinematic parameters. Firstly, a preliminary hand-eye calibration method is introduced to compensate for measurement errors at observation points, leveraging geometric-constraint-based optimization and a virtual single point derived via the barycentric calculation method. Subsequently, a distance-constrained calibration method is proposed to jointly estimate the hand-eye transformation and robot kinematic parameters, wherein a distance error model is constructed to link parameter errors with the measured deviations of a virtual single point. Finally, calibration and validation experiments were carried out, and the results indicate that the maximum and average measurement errors were reduced from 1.053 mm and 0.814 mm to 0.421 mm and 0.373 mm, respectively, thereby confirming the effectiveness of the proposed method.

Indexed as

error correctiongeometric constraintshand-eye calibrationkinematic parameter calibrationrobotic 3D scanning system

Identifiers

PMID40807827
PMCPMC12349041

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.