Evidence map›Paper›PMID 40805571›Full record

ArticleMaterials (Basel, Switzerland)2025

The Impact of an Object's Surface Material and Preparatory Actions on the Accuracy of Optical Coordinate Measurement.

Danuta Owczarek, Ksenia Ostrowska, Jerzy Sładek, Adam Gąska, Wiktor Harmatys, Krzysztof Tomczyk, Danijela Ignjatović, Marek Sieja

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Danuta OwczarekLaboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Jana Pawla II 37, 31-864 Cracow, Poland.ORCID 0009-0002-1824-9130
Ksenia OstrowskaLaboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Jana Pawla II 37, 31-864 Cracow, Poland.
Jerzy SładekLaboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Jana Pawla II 37, 31-864 Cracow, Poland.ORCID 0000-0002-5991-4988
Adam GąskaLaboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Jana Pawla II 37, 31-864 Cracow, Poland.ORCID 0000-0002-2178-3919
Wiktor HarmatysLaboratory of Coordinate Metrology, Faculty of Mechanical Engineering, Cracow University of Technology, Jana Pawla II 37, 31-864 Cracow, Poland.ORCID 0000-0003-1188-3374
Krzysztof TomczykFaculty of Electrical and Computer Engineering, Cracow University of Technology, Warszawska 24, 31-155 Cracow, Poland.ORCID 0000-0002-8922-6529
Danijela IgnjatovićCosmodromEdu, 8 Allée René Dumont, 67400 Illkirch, France.ORCID 0000-0002-4057-4303
Marek SiejaFaculty of Electrical and Computer Engineering, Cracow University of Technology, Warszawska 24, 31-155 Cracow, Poland.ORCID 0000-0001-8229-0598

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Optical coordinate measurement is a universal technique that aligns with the rapid development of industrial technologies and new materials. Nevertheless, can this technique be consistently effective when applied to the precise measurement of all types of materials? As shown in this article, an analysis of optical measurement systems reveals that some materials cause difficulties during the scanning process. This article details the matting process, resulting, as demonstrated, in lower measurement uncertainty values compared to the pre-matting state, and identifies materials for which applying a matting spray significantly improves the measurement quality. The authors propose a classification of materials into easy-to-scan and hard-to-scan groups, along with specific procedures to improve measurements, especially for the latter. Tests were conducted in an accredited Laboratory of Coordinate Metrology using an articulated arm with a laser probe. Measured objects included spheres made of ceramic, tungsten carbide (including a matte finish), aluminum oxide, titanium nitride-coated steel, and photopolymer resin, with reference diameters established by a high-precision Leitz PMM 12106 coordinate measuring machine. Diameters were determined from point clouds obtained via optical measurements using the best-fit method, both before and after matting. Color measurements using a spectrocolorimeter supplemented this study to assess the effect of matting on surface color. The results revealed correlations between the material type and measurement accuracy.

Indexed as

accuracyarticulated armlaser probelaser triangulationmetrologyoptical coordinate measurementpoint cloud

Identifiers

PMID40805571
PMCPMC12348334

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.