Evidence map›Paper›PMID 40805515›Full record

ArticleMaterials (Basel, Switzerland)2025

Development and Simulation-Based Validation of Biodegradable 3D-Printed Cog Threads for Pelvic Organ Prolapse Repair.

Ana Telma Silva, Nuno Miguel Ferreira, Henrique Leon Bastos, Maria Francisca Vaz, Joana Pinheiro Martins, Fábio Pinheiro, António Augusto Fernandes, Elisabete Silva

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ana Telma SilvaLAETA, INEGI, Rua Dr. Roberto Frias s/n, 400, 4200-465 Porto, Portugal.ORCID 0009-0008-3566-5308
Nuno Miguel FerreiraLAETA, INEGI, Rua Dr. Roberto Frias s/n, 400, 4200-465 Porto, Portugal.ORCID 0000-0002-7783-1166
Henrique Leon BastosFaculty of Engineering, University of Porto, Rua Dr. Roberto Frias s/n, 400, 4200-465 Porto, Portugal.ORCID 0009-0000-0121-4690
Maria Francisca VazLAETA, INEGI, Rua Dr. Roberto Frias s/n, 400, 4200-465 Porto, Portugal.ORCID 0009-0004-9793-4076
Joana Pinheiro MartinsLAETA, INEGI, Rua Dr. Roberto Frias s/n, 400, 4200-465 Porto, Portugal.ORCID 0000-0003-3776-9836
Fábio PinheiroLAETA, INEGI, Rua Dr. Roberto Frias s/n, 400, 4200-465 Porto, Portugal.ORCID 0000-0003-0569-995X
António Augusto FernandesLAETA, INEGI, Rua Dr. Roberto Frias s/n, 400, 4200-465 Porto, Portugal.ORCID 0000-0002-7146-9944
Elisabete SilvaLAETA, INEGI, Rua Dr. Roberto Frias s/n, 400, 4200-465 Porto, Portugal.ORCID 0000-0003-2889-4969

Funding

FCT 2021.00077.CEECINDFCT LAETA-LA/P/0079/2020FCT PhD grant 2024.00925.BDFCT PRECOGFIL- 327 PTDC/EMD-EMD/2229/2020
6 · The paper itself

Abstract

Pelvic organ prolapse (POP) is a prevalent condition, affecting women all over the world, and is commonly treated through surgical interventions that present limitations such as recurrence or complications associated with synthetic meshes. In this study, biodegradable poly(ϵ-caprolactone) (PCL) cog threads are proposed as a minimally invasive alternative for vaginal wall reinforcement. A custom cutting tool was developed to fabricate threads with varying barb angles (90°, 75°, 60°, and 45°), which were produced via Melt Electrowriting. Their mechanical behavior was assessed through uniaxial tensile tests and validated using finite element simulations. The results showed that barb orientation had minimal influence on tensile performance. In simulations of anterior vaginal wall deformation under cough pressure, all cog thread configurations significantly reduced displacement in the damaged tissue model, achieving values comparable to or even lower than those of healthy tissue. A ball burst simulation using an anatomically accurate model further demonstrated a 13% increase in reaction force with cog thread reinforcement. Despite fabrication limitations, this study supports the biomechanical potential of 3D-printed PCL cog threads for POP treatment, and lays the groundwork for future in vivo validation.

Indexed as

biodegradable cog threadsfinite element analysis (FEA)pelvic organ prolapse (POP)vaginal wall reinforcement

Identifiers

PMID40805515
PMCPMC12348529

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.