Evidence map›Paper›PMID 40802781›Full record

ArticlePloS one2025

A multimodal deep learning radiomics model for predicting degenerative meniscus tear after arthroscopy.

Yao He, Jiaying Wei, Yinsong Sun, Wei Bao, Denghua Huang, Yuanjun Fan, Wei Huang, Tingting Wang

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yao HeDepartment of Orthopedics, Banan Hospital of Chongqing Medical University, Chongqing, China.
Jiaying WeiDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Yinsong SunDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Wei BaoDepartment of Orthopedics, Banan Hospital of Chongqing Medical University, Chongqing, China.
Denghua HuangDepartment of Orthopedics, Banan Hospital of Chongqing Medical University, Chongqing, China.
Yuanjun FanDepartment of Orthopedics, Banan Hospital of Chongqing Medical University, Chongqing, China.
Wei HuangDepartment of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Tingting WangGeneral Committee Office, Banan Hospital of Chongqing Medical University, Chongqing, China.ORCID https://orcid.org/0009-0006-1616-1433

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDegenerative meniscus tears are often accompanied by varying degrees of osteoarthritis, making the prognostic outcome of arthroscopic partial meniscectomy (APM) difficult to predict. Our research objective is to develop and validate a multimodal deep learning radiology (MDLR) model based on the integration of multimodal data using deep learning radiology (DLR) scores from preoperative magnetic resonance imaging (MRI) images and clinical variables. MATERIALS AND

methodsFrom February 2020 to February 2022, 452 eligible patients with degenerative meniscus tear who underwent APM were retrospectively enrolled in cohorts. DLR features were extracted from MRI of the patient's knee. Then, an MDLR model was used for the patient prognosis after arthroscopy. The MDLR model for prognostic risk stratification incorporated DLR signatures and clinical variable.

resultsThe standalone DLR model performed poorly, with a micro average receiver operating characteristic (ROC) curve and macro average ROC line of 0.780 and 0.765 in the training set, 0.747 and 0.747 in the validation set, and 0.720 and 0.732 in the test set, respectively, for predicting postoperative outcomes in degenerative meniscus tears. Multivariate analysis identified gender, height, weight, duration of pain, ESR, and VAS as indicators of poor prognosis. After combining the above clinical features, the performance of the MDLR model has been significantly improved, with the best performance achieved under the Light Gradient Boosting Machine (GBM) algorithm. The micro average ROC curve and macro average ROC line of this model for predicting the postoperative effect of degenerative meniscus tear were 0.917 and 0.919 in the training set, 0.874 and 0.882 in the validation set, and 0.921 and 0.951 in the test set, respectively. With these variables, the MDLR model provides four levels of prognosis for arthroscopic partial meniscectomy: Poor, pain relief 0-25%, Average, pain relief 25-50%, Good, pain relief 50-75%, Excellent, pain relief 75-100%.

conclusionA tool based on MDLR was developed to consider that the pain exacerbation time is an important prognosis factor for arthroscopic partial meniscectomy in degenerative meniscus tear patients. MDLR showed outstanding performance for the prognostic efficiency stratification of degenerative meniscus tear patients who underwent arthroscopic partial meniscectomy and may help physicians with therapeutic decision making and surveillance strategy selection in clinical practice.

Indexed as

ArthroscopyDeep LearningTibial Meniscus InjuriesAdultFemaleHumansMagnetic Resonance ImagingMaleMeniscectomyMiddle AgedPrognosisRadiomicsRetrospective StudiesROC Curve

Identifiers

PMID40802781
PMCPMC12349716

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.