Evidence map›Paper›PMID 40802101›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2026

Exploring the role of the electrically evoked Vestibulo-Ocular reflex in vestibular implant surgery.

Stan C J van Boxel, Bernd L Vermorken, Benjamin Volpe, Nils Guinand, Angélica Perez-Fornos, Elke M J Devocht, Raymond van de Berg

Abstract read
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Stan C J van BoxelDepartment of Otorhinolaryngology and Head and Neck Surgery, Division of Vestibular Disorders, Maastricht University Medical Center, Maastricht, The Netherlands. stan.van.boxel@mumc.nl.ORCID http://orcid.org/0000-0002-9647-5056
Bernd L VermorkenDepartment of Otorhinolaryngology and Head and Neck Surgery, Division of Vestibular Disorders, Maastricht University Medical Center, Maastricht, The Netherlands.ORCID http://orcid.org/0000-0003-2406-8141
Benjamin VolpeDepartment of Otorhinolaryngology and Head and Neck Surgery, Division of Vestibular Disorders, Maastricht University Medical Center, Maastricht, The Netherlands.ORCID http://orcid.org/0009-0007-1125-9295
Nils GuinandService of Otorhinolaryngology Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals, Geneva, Switzerland.ORCID http://orcid.org/0000-0001-6004-8768
Angélica Perez-FornosService of Otorhinolaryngology Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals, Geneva, Switzerland.ORCID http://orcid.org/0000-0003-3911-8826
Elke M J DevochtDepartment of Otorhinolaryngology and Head and Neck Surgery, Division of Vestibular Disorders, Maastricht University Medical Center, Maastricht, The Netherlands.ORCID http://orcid.org/0000-0001-5017-316X
Raymond van de BergDepartment of Otorhinolaryngology and Head and Neck Surgery, Division of Vestibular Disorders, Maastricht University Medical Center, Maastricht, The Netherlands.ORCID http://orcid.org/0000-0001-9734-8668

Funding

Stichting De Weijerhorst Stichting De WeijerhorstStichting Het Heinsius-Houbolt Fonds Stichting Het Heinsius-Houbolt Fonds
6 · The paper itself

Abstract

purposeVestibular implantation holds considerable potential as a therapeutic strategy for individuals with vestibular loss. A correct position of the stimulation electrodes is essential for effective implant functionality. For vestibular implants targeting the semi-circular canals, Vestibulo-Ocular Reflex testing (VOR testing) is used to evaluate functionality postoperatively. It might also be an effective tool for intraoperative decision making related to electrode placement. This study aimed to evaluate the predictive value of intraoperative VOR testing for the postoperative vestibular implant response. This would be the first step in exploring the usability of the VOR as intraoperative electrode placement indicator.

methodsNine patients with bilateral vestibulopathy were implanted with an investigational vestibulo-cochlear implant. Vestibulo-ocular reflexes (VOR) were electrically evoked using the implant, both intra- and postoperatively, and recorded using video-oculography. The correspondence between the intra- and postoperative measurements was evaluated. This included the presence of the VOR, activation threshold, eye velocity and alignment. Furthermore, the correlation between the intraoperative peak eye velocity and stimulation amplitude was assessed.

resultsIt was found that the presence of an intraoperative VOR has a high positive predictive value (1.0) for predicting the presence of a postoperative VOR. Additionally, the intraoperative VOR showed a high, though not perfect, negative predictive value (0.86) for predicting the absence of a postoperative VOR. The VOR activation threshold was higher, eye velocity was lower, and alignment differed on individual level, in the intra-operative measurements compared to the post-operative measurements. The intraoperative VOR peak eye velocity was related to stimulation amplitude.

conclusionIntraoperative VOR responses during vestibular implant surgery differ from postoperative responses, likely due to general anaesthesia. Despite this discrepancy, the presence of an intraoperative VOR is a strong predictor of postoperative VOR presence. Furthermore, intraoperative VOR eye velocity increases with higher stimulation amplitudes. These findings suggest that intraoperative VOR testing may aid in optimizing electrode placement during vestibular implant surgery.

Indexed as

Bilateral VestibulopathyCochlear ImplantsReflex, Vestibulo-OcularAdultAgedElectric StimulationFemaleHumansMaleMiddle Aged

Identifiers

PMID40802101
PMCPMC12904894

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.