Evidence map›Paper›PMID 40801070›Full record

ArticleAdvanced healthcare materials2025

Conducting Polymer Coatings for Bioelectronic Arthroscopy Probes.

Sara Ebrahimi, Sadaf Khoomortezaei, Jiaxin Fan, Kathel Dongnang, Martin Garon, Eric Quenneville, Fabio Cicoira

Abstract read
In one paragraph

Article in Advanced healthcare materials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sara EbrahimiDepartment of Chemical Engineering, Polytechnique Montreal, Montreal, H3T 1J4, Canada.ORCID 0000-0002-4309-5367
Sadaf KhoomortezaeiDepartment of Chemical Engineering, Polytechnique Montreal, Montreal, H3T 1J4, Canada.ORCID 0009-0000-7835-072X
Jiaxin FanDepartment of Chemical Engineering, Polytechnique Montreal, Montreal, H3T 1J4, Canada.ORCID 0000-0001-6033-174X
Kathel DongnangDepartment of Chemical Engineering, Polytechnique Montreal, Montreal, H3T 1J4, Canada.ORCID 0000-0003-3932-1955
Martin GaronBiomomentum Inc., 1980 Michelin St., Laval, Montreal, H7L 5C2, Canada.ORCID 0009-0009-8824-781X
Eric QuennevilleBiomomentum Inc., 1980 Michelin St., Laval, Montreal, H7L 5C2, Canada.ORCID 0000-0001-6430-2102
Fabio CicoiraDepartment of Chemical Engineering, Polytechnique Montreal, Montreal, H3T 1J4, Canada.ORCID 0000-0002-0047-608X

Funding

Fonds de recherche du Québec - Nature et technologies (FRQNT, Doctoral program))Natural Sciences and Engineering Research Council of Canada ALLRP 568608 - 21NSERC Canada Graduate Scholarship (Master's and Postdoctoral program)PRIMA Québec (Research and Development in Advanced Materials Program) R22-46-006Vanier Canada Graduate Scholarship
6 · The paper itself

Abstract

This study presents conducting polymer coatings as an effective strategy to enhance the performance of electromechanical arthroscopy probes by significantly reducing electrical equilibration time (the period a surgeon must wait for the probe signal to stabilize before measurement) and improving signal stability. Microelectrodes coated with poly(3,4-ethylenedioxythiophene, PEDOT) reach electrical equilibrium in physiological medium within 10 s, compared to over 2 min for standard electroless nickel immersion gold-based (ENIG) probes and ≈20 s for electrodeposited gold, thereby eliminating impractical delays during arthroscopic procedures. PEDOT coatings also reduce impedance by two to three orders of magnitude at low frequencies (<1 kHz), minimizing sensitivity to hand motion and reducing the likelihood of repeated measurements. Importantly, these electrodes maintain their functionality after sterilization and repeated use, demonstrating high reliability for intraoperative applications. Furthermore, PEDOT-coated nickel-phosphorus (Ni-P) microelectrodes offer a gold-free, cost-effective, and sustainable alternative. As osteoarthritis continues to affect a growing global population, the development of rapid, durable, and accessible diagnostic tools is increasingly critical. The integration of PEDOT into arthroscopic microelectrodes represents a clinically promising approach to faster, more efficient cartilage assessment while reducing reliance on critical raw materials.

Indexed as

ArthroscopyBridged Bicyclo Compounds, HeterocyclicCoated Materials, BiocompatiblePolymersElectric ConductivityGoldHumansMicroelectrodesNickelBridged Bicyclo Compounds, HeterocyclicCoated Materials, BiocompatibleGoldNickelpoly(3,4-ethylene dioxythiophene)Polymersarthroscopy probesconducting polymerselectrodepositionorganic bioelectronicsPEDOT

Identifiers

PMID40801070
PMCPMC12538537

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.