ArticleClinical ophthalmology (Auckland, N.Z.)2025
ICL Exchanges or Explants Due to Sizing in a United States High Volume Center.
Article in Clinical ophthalmology (Auckland, N.Z.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Retrospective Validation of an AI Based Tool for Vault Prediction After Implantable Collamer Lens Surgery for High Myopia.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To report the incidence, reasons, and outcomes for Implantable Collamer Lens (ICL) exchanges at a high-volume center in the United States. Patients and Methods: A retrospective chart review was performed on 961 eyes of 484 patients who underwent ICL surgery in a commercial setting at Parkhurst NuVision from 04/06/2022 to 10/21/2024. Results: 11 eyes of 8 patients out of the 961 commercial cases (1.1%) underwent ICL exchange at our institution due to sizing issues. Of these, only 5 cases (0.5%) were exchanged due to initial vault concerns with 6 cases (0.6%) exchanged due to rotated toric ICLs. Upon repeat review of these cases, we would have chosen a different size in 3 of them. Conclusion: ICL implantation is remarkably safe, with an incredibly low exchange rate due to inappropriate sizing. The majority of these cases also involved clinically safe vault and the exchange only occurred due to rotation of a toric ICL.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.