ArticleImaging neuroscience (Cambridge, Mass.)2024
Optimising the sensitivity of optically-pumped magnetometer magnetoencephalography to gamma band electrophysiological activity.
Article in Imaging neuroscience (Cambridge, Mass.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Neuromagnetism "On the Cheap": Evaluating a Combined Cylindrical Shield and Partial-Coverage OPM-MEG System for Detecting Sensorimotor Responses in Humans.Sensors (Basel, Switzerland) · 2026Article
- Revolutionizing Pediatric Neurophysiology With Magnetoencephalography.Psychophysiology · 2026Review
- Chip-scale packaged in-line polarization-resolved detector for optically pumped magnetometers.Microsystems & nanoengineering · 2026Article
- Assessing the stability of evoked, induced, and passive MEG responses for repeat testing with optically pumped magnetometers.Scientific reports · 2025Article
- Article
- Biplanar Nulling Coil System for OPM-MEG Using Printed Circuit Boards.Sensors (Basel, Switzerland) · 2025Article
- Source reconstruction without an MRI using optically pumped magnetometer-based magnetoencephalography.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- Measuring the neurodevelopmental trajectory of excitatory-inhibitory balance via visual gamma oscillations.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- Determining sensor geometry and gain in a wearable MEG system.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- Demonstrating equivalence across magnetoencephalography scanner platforms using neural fingerprinting.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- Towards a 384-channel magnetoencephalography system based on optically pumped magnetometers.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- A novel, robust, and portable platform for magnetoencephalography using optically-pumped magnetometers.Imaging neuroscience (Cambridge, Mass.) · 2024Article
- Article
- The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG study.bioRxiv : the preprint server for biology · 2024Article
- A Novel, Robust, and Portable Platform for Magnetoencephalography using Optically Pumped Magnetometers.bioRxiv : the preprint server for biology · 2024Article
- Simultaneous whole-head electrophysiological recordings using EEG and OPM-MEG.Imaging neuroscience (Cambridge, Mass.) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
The measurement of electrophysiology is of critical importance to our understanding of brain function. However, current non-invasive measurements-electroencephalography (EEG) and magnetoencephalography (MEG)-have limited sensitivity, particularly compared to invasive recordings. Optically-Pumped Magnetometers (OPMs) are a new type of magnetic field sensor which ostensibly promise MEG systems with higher sensitivity; however, the noise floor of current OPMs remains high compared to cryogenic instrumentation and this limits the achievable signal-to-noise ratio of OPM-MEG recordings. Here, we investigate how sensor array design affects sensitivity, and whether judicious sensor placement could compensate for the higher noise floor. Through theoretical analyses, simulations, and experiments, we use a beamformer framework to show that increasing the total signal measured by an OPM array-either by increasing the number of sensors and channels, or by optimising the placement of those sensors-affords a linearly proportional increase in signal-to-noise ratio (SNR) following beamformer reconstruction. Our experimental measurements confirm this finding, showing that by changing sensor locations in a 90-channel array, we could increase the SNR of visual gamma oscillations from 4.8 to 10.5. Using a 180-channel optimised OPM-array, we capture broadband gamma oscillations induced by a naturalistic visual paradigm, with an SNR of 3; a value that compares favourably to similar measures made using conventional MEG. Our findings show how an OPM-MEG array can be optimised to measure brain electrophysiology with the highest possible sensitivity. This is important for the design of future OPM-based instrumentation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.