Evidence map›Paper›PMID 40800423›Full record

ArticleImaging neuroscience (Cambridge, Mass.)2024

Investigating the effective temporal resolution in a task-based functional MRI experiment at 7 T MRI using a dynamic phantom.

Guy Baz, Rita Schmidt

Abstract read
In one paragraph

Article in Imaging neuroscience (Cambridge, Mass.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Guy BazWeizmann Institute of Science, Department of Brain Sciences, Rehovot, Israel.
Rita SchmidtWeizmann Institute of Science, Department of Brain Sciences, Rehovot, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An increasing number of human fMRI studies aim to discern the time delays between evoked responses under different stimuli conditions in different brain regions. To achieve that, a primary goal is to acquire fMRI data with high sampling rates. This task is now possible with ultra-high field (≥7 T) MRI and the advancement of imaging acceleration methods. Consequently, it becomes imperative to understand what is the actual or effective temporal resolution (ETR) that is realized in given settings of an fMRI experiment. In this study, we utilized a dynamic phantom to reliably repeat a set of scans, generating a "ground truth" signal with controllable onset delays mimicking fMRI responses in a task-based block-designed fMRI. Here, we define the ETR and quantify a scan's ETR using the dynamic phantom. The quantification was performed for various scanning parameters, including echo time (TE), repetition time (TR), voxel size, and contrast-to-noise ratio (CNR). We further show that combining data from multi-echo EPI can improve the ETR (i.e., reduce it). In addition, parameters of the fMRI paradigm were examined, including the blocks' length and density. As tissue properties (e.g., level of iron deposition) affect the CNR and thus change the ETR, we examined the signal rise mimicking not only the cortex, but also the basal ganglia (known for its high iron deposition). Combining multi-echo data, the estimated ETR for the examined scans was 151 ms for a cortex-mimicking setup and 248 ms for a basal ganglia-mimicking setup, when scanning with a sampling time (i.e., TR) of 600 ms. Yet, a substantial penalty was paid when the CNR was low, in which case the ETR was even larger than the TR. A feasibility set of experiments was also designed to evaluate how the ETR is affected by physiological signal fluctuations and the variability of the hemodynamic response. This study shows the viability of studying time responses with fMRI, by demonstrating that a very short ETR can be achieved. However, it also emphasizes the need to examine the attainable ETR for a particular experiment.

Indexed as

functional MRImulti-echotemporal resolutionultra-high field MRI

Identifiers

PMID40800423
PMCPMC12290576

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.