Evidence map›Paper›PMID 40799062›Full record

ArticleMolecular imaging and radionuclide therapy2025

Investigation of the Partial Volume Effect in Pre-Dosimetry of Liver Tumors for

Ayşe Dilaver Akar, Nami Yeyin, Sinem Akyol, Özge Demir, Eylem Gülce Çoker, Mustafa Demir

Abstract read
In one paragraph

Article in Molecular imaging and radionuclide therapy, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ayşe Dilaver Akarİstanbul Aydın University, Graduate Education Institute, Health Physics Program, İstanbul, Türkiye.ORCID 0009-0006-7402-8315
Nami Yeyinİstanbul University-Cerrahpaşa, Cerrahpaşa Faculty of Medicine, Department of Nuclear Medicine, İstanbul, Türkiye.ORCID 0000-0003-0262-4020
Sinem Akyolİstanbul University-Cerrahpaşa, Cerrahpaşa Faculty of Medicine, Department of Nuclear Medicine, İstanbul, Türkiye.ORCID 0000-0003-3056-7035
Özge Demirİstanbul University-Cerrahpaşa, Cerrahpaşa Faculty of Medicine, Department of Chemical Engineering, İstanbul, Türkiye.ORCID 0000-0002-0342-5915
Eylem Gülce Çokerİstanbul Aydın University, Graduate Education Institute, Health Physics Program, İstanbul, Türkiye.ORCID 0000-0001-6361-9458
Mustafa Demirİstanbul University-Cerrahpaşa, Cerrahpaşa Faculty of Medicine, Department of Nuclear Medicine, İstanbul, Türkiye.ORCID 0000-0002-9813-1628

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Yttrium-90 ( Methods: In this experimental study, a custom-designed liver phantom containing four tumor mimics with diameters of 1 cm, 2 cm, 3 cm, and 5 cm was used. The tumor and liver parenchyma volumes were filled with Tc-99m at a ratio of 4.86: 1. The phantom was imaged in a water tank using SPECT/CT according to standard clinical protocols. Volumetric regions of interest were drawn for each lesion and tumor volumes, contrast values (C), contrast to noise ratios (CNR), and absorbed tumor doses were calculated from the counts obtained. Since this study does not involve live subjects and was conducted solely on a phantom model, ethical approval, informed consent, and consent forms are not required for this study. Results: Tumor diameters measured on SPECT/CT images matched those obtained from both CT images and the actual dimensions. The contrast values calculated from the SPECT/CT images for lesions with diameters of 2 cm and 5 cm were 2.03 and 3.89, respectively. Similarly, the corresponding CNR values were 8.64 and 21.07. Tumor-to-normal tissue ratios were 2.03 and 3.89 for the 2 cm and 5 cm lesions, respectively. For the 2 cm lesion, the actual and SPECT/CT-derived absorbed doses were 15.3 Gy and 7.87 Gy, respectively. For the 5 cm lesion, these values were 15.4 Gy and 13.38 Gy, respectively. The absorbed tumor doses significantly decreased as tumor diameter decreased due to the influence of PVE. Conclusion: Tumors smaller than 2 cm in diameter were markedly affected by the PVE. Considering the influence of PVE, or applying appropriate corrections in dosimetric calculations, is of critical importance for improving the accuracy of dosimetry results.

Indexed as

90Y radioembolization therapyimage qualitypartial volume effectTc-99m-MAA dosimetrytumor imaging

Identifiers

PMID40799062
PMCPMC12505186

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked