Evidence map›Paper›PMID 40798424›Full record

ArticleOptics express2025

Detection and correction of misalignment for high fidelity volumetric additive manufacturing.

Gabriel Seymour, Robert R McLeod

Abstract read
In one paragraph

Article in Optics express, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Gabriel Seymour
Robert R McLeod

Funding

Optimization of a Minimally-Invasive Bidirectional Optogenetic Peripheral Nerve Interface with Single Axon Read-in & Read-out SpecificityR01NS118188 · NINDS · UNIVERSITY OF COLORADO DENVER · PI CALDWELL, JOHN H, GIBSON, EMILY · 2020 to 2024
$3.3M
NINDS NIH HHS R01 NS118188
6 · The paper itself

Abstract

Volumetric additive manufacturing (VAM) rapidly fabricates three-dimensional polymer structures by projecting images into a rotating vial of photosensitive resin. However, inevitable misalignment of this vial, the rotation system, and the projector limit the achievable resolution, fidelity and repeatability of VAM systems. In this work, we characterize the distinct impact of common misalignments through their distortion of a spherical test object. We then show that the ensemble of misalignments can be quantified with the addition of an imaging system. This information is then used to correct for the measured misalignment by modification of the projected images to enable reliable, high-resolution VAM dose delivery.

Identifiers

PMID40798424
PMCPMC12011375

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.