Evidence map›Paper›PMID 40796789›Full record

ArticleScientific reports2025

Adaptive differential current relay based on form/ripple factors for busbar current signals.

R A Mahmoud

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

R A MahmoudDepartment of Electrical Power and Machines Engineering (PME), College of Engineering Science & Technology, Misr University for Science and Technology (MUST), 6Th of October City, Giza, Egypt. ragab.mahmoud@must.edu.eg.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents an adaptive protection algorithm that adjusts the tripping characteristics of the differential relaying schemes in response to changes in CT saturation levels and DC component content of fault currents. Moreover, the main protection function differentiates between internal and external faults with or without CT saturation. This is accomplished by estimating the appropriate tripping characteristic slope using form and ripple factors calculated for the current signals measured at the entering and exiting terminals of the protected equipment. The modified approach aims to achieve automatic resetting to inhibit the relay operation during external faults and to avoid any delay or restriction of the relay operation during severe internal faults due to the presence of harmonics. Numerous cases, including various types of internal and external faults with or without CTs saturation and DC component, are carried out on a typical power system simulated using the ATP platform. The proposed algorithm can be performed utilizing the MATLAB software, which can receive current measurements from the ATP simulator. The simulation results manifest the functional efficiency of the suggested technique under diverse operating and fault conditions and its ability to discriminate fault location. Additionally, the response time of the suggested technique is roughly 10.0 ms in the event of internal faults, which is also appropriate for preventing the technique from functioning in the case of non-fault or external fault disturbances. Furthermore, it is able to recognize CT saturation conditions, assess the degree of current distortion, and select which feeder CT is saturated. Besides, the outcomes demonstrate the extreme simplicity, effectiveness, stability, accuracy, and reliability of the proposed algorithm. Quantitative findings from the extensive case studies indicate that the estimated ratios of the protection's accuracy, dependability, security, and reliability are greater than 99.40%. It is applicable to Smart Grids (SGs) and Substation Automation Systems (SAS), as the algorithm is one of the applications in digital protection relays/systems.

Indexed as

Adaptive relaysCT saturationDC componentDifferential current relaysFault currentsForm factorRipple factor

Identifiers

PMID40796789
PMCPMC12344150

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.