ArticleEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2025
Dual energy for pulmonary vein isolation using focal ablation technology integrated with a three-dimensional mapping system: SmartfIRE 12-month results.
Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05752487 (Safety and Effectiveness Evaluation of the THERMOCOOL SMARTTOUCH SF Catheter With the TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation), which is not on this map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Safety and Effectiveness Evaluation of the THERMOCOOL SMARTTOUCH SF Catheter With the TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation (PAF)
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Guideline
- Safety and effectiveness of the TactiFlex duo system: 6-month results of the FOCALFLEX study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Trial
- Ablation in Complex Adult Congenital Heart Disease: Versatility Matters.JACC. Case reports · 2026Article
- From Shots to Shocks: When Ethanol Isn't RF's Friend-Pericardial-Esophageal Fistula After Combined Ethanol and Radiofrequency Ablation.JACC. Case reports · 2026Article
- Review
- Pulmonary Vein Isolation: Comparing different energy sources - independent or complementary use?Indian pacing and electrophysiology journalReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors.
Funding
Abstract
aimsThe multicentre, single-arm SmartfIRE study assessed the safety and effectiveness of the novel dual-energy THERMOCOOL SMARTTOUCH SF (DE STSF) contact-force sensing catheter with multimodality generator to deliver radiofrequency (RF) and unipolar biphasic pulsed field (PF) ablation. Three-month follow-up showed a 100% acute success rate with an acceptable safety profile. Results at 12 months postablation are summarized here. METHODS AND
resultsPatients with symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation with the recommendation of PF ablation at posterior/inferior and RF ablation at the anterior/ridge/carina segments. The 12-month effectiveness endpoint was freedom from documented symptomatic and asymptomatic atrial arrhythmia on or off antiarrhythmic therapy (assessed by electrocardiogram, remote arrhythmia monitoring, and 24-h Holter), including acute procedural failures. Safety was assessed as the incidence of serious adverse events (SAEs) related to device and/or procedure. Quality of life was evaluated via Atrial Fibrillation Effect on Quality-of-Life (AFEQT) scores, and healthcare utilization was assessed as hospitalization for cardiovascular events and antiarrhythmic drug (AAD) use. Of 149 patients enrolled, 140 had the study catheter inserted (safety population analysis set), and 136 met the eligibility criteria and had ablation energy delivered (per-protocol analysis set). Freedom from symptomatic and asymptomatic atrial arrhythmia at 12 months was 71.5% (84.2% when using standard-of-care monitoring only). The clinical success rate (freedom from symptomatic arrhythmia) was 86.4%, and single procedural success was 81.0% (n = 136). The rate of device- and/or procedure-related SAEs was 3.6% (5/140 patients; two cardiac tamponades, two pulmonary vein stenosis, one anaphylactic shock). At 12 months, the overall AFEQT score increased by a median 26.9 points vs. baseline. Cardiovascular hospitalization rate reduced from 20.1 to 11.9% during the 12 months before vs. after ablation, respectively. The use of Class I/III AAD decreased from 60.3% at baseline to 23.9% at 6-12 months postablation. Post hoc analysis showed that patients with high adherence to recommended inter-tag distance and PF/RF index during ablation (n = 47) had a 12-month freedom from atrial arrhythmia recurrence of 86.9%, while the remaining patients (n = 88) had a rate of 64.0%.
conclusionThe 12-month follow-up of the SmartfIRE study demonstrated the effectiveness, safety, and healthcare benefits of ablation using the DE STSF platform. CLINICAL
trial registrationClinicalTrials.gov Identifier: NCT05752487(https://clinicaltrials.gov/study/NCT05752487).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.