Evidence map›Paper›PMID 40795650›Full record

ArticleInterdisciplinary cardiovascular and thoracic surgery2025

Early Haemodynamic Performance and Clinical Outcomes of a Novel Bioprosthetic Mitral Valve.

Yuki Wada, Akira Marui, Atsushi Nagasawa, Shinichi Tsumaru, Keisuke Hakamada, Kazuya Terazono, Yuta Kitagata, Hironori Mihara, Nobuhisa Ohno

Abstract read
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yuki WadaDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.ORCID 0000-0003-4314-2001
Akira MaruiDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.
Atsushi NagasawaDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.
Shinichi TsumaruDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.ORCID 0000-0001-6966-8541
Keisuke HakamadaDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.
Kazuya TerazonoDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.
Yuta KitagataDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.
Hironori MiharaDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.
Nobuhisa OhnoDepartment of Cardiovascular Surgery, Kokura Memorial Hospital, Kitakyushu 802-8555, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe MITRIS RESILIA mitral bioprosthesis is a novel pericardial valve developed to improve durability and haemodynamic performance. However, clinical data on its use in mitral valve replacement are limited. This single-center retrospective study aimed to evaluate the early haemodynamic performance and clinical outcomes of the MITRIS RESILIA valve in patients requiring mitral valve replacement.

methodsWe retrospectively reviewed data from 66 patients who underwent mitral valve replacement using MITRIS RESILIA between May 2021 and May 2024. Transthoracic echocardiography was used to assess valve haemodynamic performance at discharge, 1 year, and 2 years postoperatively. The primary end-point was early valve haemodynamics, and the secondary end-points were overall survival and structural valve deterioration.

resultsThe mean age of the cohort was 75.0 ± 5.8 years, and 48.5% of the patients were male. The mean pressure gradient was 3.9 ± 1.4 mmHg at discharge, 4.0 ± 2.0 mmHg at 1 year, and 3.9 ± 1.3 mmHg at 2 years. The effective orifice area was 1.52 ± 0.50 cm2 after surgery. None of the patients experienced structural valve deterioration or significant paravalvular leak. The rate of freedom from all-cause mortality at 2 years was 93.3%.

conclusionsMITRIS RESILIA demonstrated stable early haemodynamic performance across all valve sizes, including the 23 mm prosthesis. No cases of structural valve deterioration or paravalvular leak were observed, supporting its feasibility for mitral valve replacement. Further studies with extended follow-up are required to confirm the long-term durability and clinical benefits of the valve.

Indexed as

BioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsMitral ValveMitral Valve InsufficiencyAgedAged, 80 and overFemaleHumansMaleProsthesis DesignRetrospective StudiesTime FactorsTreatment Outcomebioprosthetic valvemitral valve replacementMITRIS RESILIAstructural valve deteriorationvalve haemodynamics

Identifiers

PMID40795650
PMCPMC12448282

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.