ArticleMedical physics2025
New energy layer reduction method for rapid intensity-modulated proton therapy (IMPT) using a ridge filter.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Commissioning and Validation of a Synchrocyclotron - Based Ultra-High-Dose-Rate Beamline for FLASH.International journal of particle therapy · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
backgroundEfficient delivery of intensity-modulated proton therapy (IMPT) plays a pivotal role in improving the effectiveness of proton therapy. Accelerating delivery not only increases patient throughput but also improves the ability to manage dynamic target motion and reduces uncertainties, thereby enhancing treatment accuracy. Additionally, rapid delivery enables the effective use of breath-hold techniques, allowing for smaller target margins and providing better protection for healthy tissues. Since energy layer switching time constitute the majority of delivery time, reducing the number of energy layers can be highly beneficial for improving delivery efficiency. PURPOSE: This work proposes a novel energy layer reduction method for rapid IMPT using a ridge filter.
methodsThe width of the Bragg peak (BP) is extended using a ridge filter, referred to as the extended Bragg peak (EBP). The machine file of the generated EBP is subsequently incorporated in our in-house treatment planning system for inverse planning. The extended peak width reduces the number of energy layers required for target coverage. However, relying solely on EBP can compromise the accuracy of energy modulation. To address this limitation, pristine BP is utilized to fill small gaps left by EBP and ensure rapid dose fall-off at the distal and proximal edges of the target. To optimize the selection of BP and EBP energies, the problem is formulated as a mathematical model incorporating a group sparsity constraint. The model is then solved by a variant of block orthogonal matching pursuit algorithm, which selects BP and EBP energies in a greedy manner.
resultsThe combined use of BP and EBP, referred to as the BP-EBP, considerably reduced the number of energy layers required compared to conventional IMPT. For example, in an abdomen case, the BP-EBP method decreased the energy layers from 79 to 28 (11 for BP and 17 for EBP) while maintaining comparable plan quality. Similarly, in a lung case, it reduced the energy layers from 70 to 30 (9 for BP and 21 for EBP), achieving slightly better plan quality than the conventional approach. Moreover, the BP-EBP reduced delivery time by more than 50% in both cases compared to conventional IMPT. Furthermore, the feasibility of BP-EBP was experimentally demonstrated on the ProteusONE proton therapy system.
conclusionsA novel energy reduction method is proposed and experimentally demonstrated that leverages BP and EBP generated by a ridge filter that significantly decreases the number of energy levels required in IMPT, thereby enhancing delivery efficiency.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.