Evidence map›Paper›PMID 40789571›Full record

ArticleInternational journal for numerical methods in biomedical engineering2025

The Effects of Vertebral Body Tethering on the Intervertebral Discs and Facet Joints: A Numerical Analysis.

Luis Fernando Nicolini, Rafael Carreira Oliveira, Vitor Hugo Tramontini, Marx Ribeiro, Carlos Rodrigo de Mello Roesler, Eduardo Alberto Fancello

Abstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. The Effects of Vertebral Body Tethering on the Intervertebral Discs and Facet Joints: A Numerical Analysis.International journal for numerical methods in biomedical engineering · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Luis Fernando NicoliniDepartment of Mechanical Engineering, Federal University of Santa Maria, Santa Maria, Brazil.ORCID https://orcid.org/0000-0003-0332-1750
Rafael Carreira OliveiraGroup of Analysis and Mechanical Design-GRANTE, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis, Brazil.
Vitor Hugo TramontiniDepartment of Mechanical Engineering, Federal University of Santa Maria, Santa Maria, Brazil.
Marx RibeiroGroup of Analysis and Mechanical Design-GRANTE, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis, Brazil.ORCID https://orcid.org/0000-0003-3341-3605
Carlos Rodrigo de Mello RoeslerBiomechanical Engineering Laboratory-LEBm, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis, Brazil.
Eduardo Alberto FancelloGroup of Analysis and Mechanical Design-GRANTE, Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis, Brazil.ORCID https://orcid.org/0000-0001-9085-3901

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Anterior vertebral body tethering (VBT) is a promising technique for the treatment of adolescent idiopathic scoliosis. However, the segments directly treated with VBT can experience substantial loads resulting from the tether pretension, which may alter internal stresses and potentially compromise structures such as the intervertebral discs (IVDs) and facet joints. We aim to investigate the effects of tether within the VBT on the L1-L2 IVD stresses and contact forces of the facet joints, using an extensively calibrated and validated finite element model of the T10-S1 spine. The implant was inserted on the left side of the T10-L3 and tensioned up to 300 N representing the tether pretension applied during surgery and the case of the postoperative neutral position. Subsequently, the spine was tested under an external pure moment of 8 Nm. The tether pretension resulted in a significant increase in the IVD stresses. In the neutral position, a gradual increase in intervertebral pressure (IDP) at the center of the IVD of 0.094, 0.181, and 0.267 MPa was observed after applying forces of 100, 200, and 300 N to the tether, respectively. The contact force of the left facet joint also increased with pretension. It was 12.5 N for the native spine and gradually increased to 49.5, 82.0, and 100.9 N for tether pretensions of 100, 200, and 300 N, respectively, during extension. These results indicate that tether pretension is a key parameter that increases the internal stresses of the IVD and the contact forces of the facet joints at the implant side.

Indexed as

Intervertebral DiscVertebral BodyZygapophyseal JointAdolescentBiomechanical PhenomenaFinite Element AnalysisHumansLumbar VertebraeScoliosisStress, Mechanicalcurve correctiondegenerationfinite element methodscoliosisspinevertebral body tethering

Identifiers

PMID40789571
PMCPMC12339148

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.