Evidence map›Paper›PMID 40788896›Full record

ArticlePloS one2025

Effects of germicidal far-UVC on ozone and particulate matter in a conference room.

Farideh Hosseini Narouei, Zifeng Tang, Shiqi Ian Wang, Raabia H Hashmi, David Welch, Sandhya Sethuraman, David J Brenner, V Faye McNeill

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Farideh Hosseini NaroueiDepartment of Chemical Engineering, Columbia University, New York, New York, United States of America.
Zifeng TangDepartment of Chemical Engineering, Columbia University, New York, New York, United States of America.
Shiqi Ian WangDepartment of Chemical Engineering, Columbia University, New York, New York, United States of America.
Raabia H HashmiCenter for Radiological Research, Columbia University Irving Medical Center, New York, New York, United States of America.
David WelchCenter for Radiological Research, Columbia University Irving Medical Center, New York, New York, United States of America.
Sandhya SethuramanDepartment of Chemical Engineering, Columbia University, New York, New York, United States of America.
David J BrennerCenter for Radiological Research, Columbia University Irving Medical Center, New York, New York, United States of America.
V Faye McNeillDepartment of Chemical Engineering, Columbia University, New York, New York, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The application of 222 nm light from KrCl excimer lamps (GUV222 or far-UVC) is a promising approach to reduce the indoor transmission of airborne pathogens, including the SARS-CoV-2 virus. GUV222 inactivates airborne pathogens and is believed to be relatively safe for human skin and eye exposure. However, UV light initiates photochemical reactions which may negatively impact indoor air quality. We conducted a series of experiments to assess the formation of ozone ([Formula: see text]), and resulting formation of secondary organic aerosols (SOA), induced by commercial far-UVC devices in an office environment (small conference room) with an air exchange rate of [Formula: see text]. We studied scenarios with a single far-UVC lamp, corresponding to the manufacturer's recommendations for disinfection of a space that size, and with four far-UVC lamps, to test conditions of greater far-UVC fluence. The single lamp did not significantly impact [Formula: see text] or fine particulate matter levels in the room. Consistent with previous studies in the literature, the higher far-UVC fluences lead to increases in [Formula: see text] of 5 to 10 ppb above background, and minor increases in particulate matter (16% ± 10 % increase in particle number count). The use of far-UVC at minimum intensities required for disinfection, and in conjunction with adequate ventilation rates (e.g. ANSI/ASHRAE recommendations), may allow the reduction of airborne pathogen levels while minimizing the formation of air pollutants in furnished indoor environments.

Indexed as

Air Pollution, IndoorDisinfectionOzoneParticulate MatterUltraviolet RaysAerosolsCOVID-19HumansSARS-CoV-2AerosolsOzoneParticulate Matter

Identifiers

PMID40788896
PMCPMC12338833

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.