Evidence map›Paper›PMID 40788402›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2025

The use of navigation to achieve planned coronal alignment during cemented revision total knee arthroplasty: a technical note and case series.

Clément Horteur, Thomas Van Den Wyngaert, Vincent Massé, Marc-Olivier Kiss

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Clément HorteurCentre Hospitalier Universitaire de Grenoble, Grenoble, France. chorteur@chu-grenoble.fr.
Thomas Van Den WyngaertUniversity of Montreal, Montreal, Canada.
Vincent MasséUniversity of Montreal, Montreal, Canada.
Marc-Olivier KissUniversity of Montreal, Montreal, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Although navigation technologies have been widely adopted over the past two decades in primary total knee arthroplasty (TKA), their application in revision total knee arthroplasty (R-TKA) remains scarcely documented. This technical note outlines a surgical protocol designed to achieve targeted coronal alignment using off-label, image-free, optical navigation during R-TKA. This technique is suitable for all image-free optical navigation systems. We report 8 cases utilizing this method. Based on postoperative long-leg radiograph measures, the mean absolute deviation from the surgical plan was 1.5° ± 1.3° (range 0.2°-3.8°) for the femur (lateral distal femoral angle) and 1.3° ± 1.5° (range 0°-4.7°) for the tibia (medial proximal tibial angle). Navigation assistance during R-TKA appears as a useful tool, particularly in cases where conventional instrumentation proves inadequate (shaft deformation, femoral canal obstruction).

Indexed as

Arthroplasty, Replacement, KneeSurgery, Computer-AssistedAgedAged, 80 and overBone CementsFemaleFemurHumansKnee JointKnee ProsthesisMaleMiddle AgedRadiographyReoperationTibiaBone CementsNavigationRevisionTotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked