SynthesisThe Cochrane database of systematic reviews2025
Amplitude-integrated electroencephalography compared with conventional video-electroencephalography for detection of neonatal seizures.
Synthesis in The Cochrane database of systematic reviews, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Amplitude-integrated electroencephalography compared with conventional video-electroencephalography for detection of neonatal seizures.The Cochrane database of systematic reviews · 2025Pooled it
- Neonatal Epilepsy: Beyond Seizures in a Developing Brain-A Narrative Review.Brain sciences · 2026Review
- Article
- Amplitude integrated electroencephalography for neonatal seizure detection: an alternative opinion to the 2025 Cochrane review.Pediatric research · 2026Article
- Possible Clinical Evidence for a Glossopharyngeal Afferent Pathway in Human Hiccup Reflexes: A Report of Two Cases.Cureus · 2026Article
- Risk factors for electrographic seizures in infants after cardiac surgery and their association with outcomes: a retrospective cohort study.Scientific reports · 2026Article
- Electrographic monitoring for seizure detection in the neonatal unit: current status and future direction.Pediatric research · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundConventional video-electroencephalography (cEEG) is the reference standard for diagnosing and managing neonatal seizures. However, continuous bedside cEEG services are not available in most neonatal units. Hence, an alternative and relatively simple method called amplitude-integrated EEG (aEEG), which uses a limited number of scalp electrodes, has become popular. aEEG allows continuous bedside monitoring of the electrical activity of the brain in neonates.
objectivesThe primary objective of the review was to assess the accuracy of aEEG against the reference standard cEEG for the detection of 'neonates with seizures' and 'individual seizures'. Detection of 'neonates with seizures' refers to the ability of the test to correctly identify a 'neonate' as 'seizure positive' or 'seizure negative' based on the detection of at least one seizure episode in the entire aEEG recording. Detection of 'individual seizures' refers to the ability of the test to correctly identify 'individual' seizure episodes within the same neonate rather than just diagnosing the neonate as 'seizure positive' or 'seizure negative'. SEARCH
methodsWe searched CENTRAL, MEDLINE, Embase, clinical trials registries, and grey literature (Open Grey, Trove, and American Doctoral Dissertations) to 26 July 2022. We did not apply any language or publication status restrictions or any other filters. SELECTION CRITERIA: We included prospective and retrospective studies investigating the accuracy of aEEG (index test) against the reference standard cEEG for the detection of neonatal seizures. To be eligible for inclusion, the studies must have compared aEEG with simultaneously recorded cEEG. There was no restriction on the number of leads, use of raw EEG traces, or experience and training of an aEEG interpreter. cEEG should have been recorded using at least nine electrodes and interpreted by a qualified person experienced in the interpretation of neonatal cEEG. DATA COLLECTION AND ANALYSIS: Working independently, two review authors collected data from the included studies in a prespecified form and assessed the quality of the included studies using the QUADAS-2 tool. For the outcome of 'neonates with seizures', we used a bivariate mixed-effects regression model to conduct a meta-analysis to derive pooled sensitivity, specificity, positive and negative likelihood ratios (LR), and their respective 95% confidence intervals (CI). We generated a summary receiver operating characteristic (SROC) curve to display the results of individual studies. We calculated post-test probabilities based on Bayes' theorem through Fagan nomograms. For the outcome of 'individual seizures', pooling of data was not possible because of the 'unit of analysis' issue. Instead, we performed a narrative synthesis. We assessed the certainty of the evidence using GRADE guidelines. MAIN
resultsWe included 16 studies (562 infants) in the systematic review, of which only two studies interpreted the aEEGs prospectively at the bedside. Out of 16 studies, three studies (97 infants) described the accuracy of aEEG only for detecting 'infants with seizures', three studies (72 infants) described only 'individual seizures', while 10 studies (393 infants) described the accuracy of aEEG for detecting both. Ten of 16 studies were conducted in term and late preterm infants. Half of the included studies did not use raw EEG traces. Fourteen studies reported outcomes based only on retrospective interpretation. Ten of 16 studies used four electrodes (making this the most common approach amongst the included studies), and 10 studies' aEEG recordings exceeded six hours. Only two included studies used a seizure detection algorithm. In 14 studies, a neonatal or neurology consultant performed aEEG interpretation, and most (in 10 of 14 studies) had prior experience in aEEG interpretation. Accuracy of aEEG to diagnose 'neonates with seizures'. The only two prospective studies (53 participants) which interpreted aEEGs 'live' at the bedside, reported sensitivities of zero and 0.57 and specificities of 0.82 and 0.92, respectively. Meta-analysis of 13 studies (490 neonates) found that aEEG had a pooled sensitivity of 0.71 (95% CI 0.57 to 0.83), specificity of 0.84 (95% CI 0.59 to 0.95), positive LR of 4.50 (95% CI 1.55 to 13.04), and negative LR of 0.34 (95% CI 0.22 to 0.53) for the detection of 'neonates with seizures'. However, when we analysed only studies with low risk of bias (3 studies), sensitivity (0.56, 95% CI 0.02 to 0.99) and specificity (0.78, 95% CI 0.60 to 0.90) were even lower. There was significant statistical heterogeneity, which could not be explained based on threshold effect and exploratory analyses of forest plots. We graded the certainty of the evidence as low, in view of the high or unclear risk of bias in many studies, imprecision, and significant heterogeneity. Accuracy of aEEG to detect 'individual seizures' in neonates. The reported sensitivities of aEEG for the detection of 'individual seizures' ranged from 0 to 0.86 (13 studies, 465 neonates). We rated the certainty of the evidence as low. The common causes of missed seizures on aEEG (i.e. false negative) as reported by studies were short duration of seizures, localisation of seizures away from aEEG leads, low voltage, and inexperienced interpreter. The false-positive rates were high when interpreted live at the bedside and if the interpreters were inexperienced. Artefacts resulting from muscle movement, patting, hiccups, and insufficient electrode attachment were other common causes of false-positive results. AUTHORS'
conclusionsLow-certainty evidence suggests that aEEG has only moderate sensitivity and specificity for detecting 'neonates with seizures', and its ability to detect 'individual seizures' varies widely. These findings suggest that aEEG may not be sufficiently accurate for diagnosing neonatal seizures as it can under-diagnose or over-diagnose seizures. Studies with low risk of bias are needed to address the issue definitively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.