Evidence map›Paper›PMID 40786917›Full record

ArticleOrthopaedic journal of sports medicine2025

Anterior Cruciate Ligament Reconstruction With Unilateral 8-Strand Hamstring Tendon Autograft Demonstrated Promising Clinical, Radiological, and Second-Look Arthroscopic Outcomes at 2-Year Minimum Follow-up.

Guanyang Song, Daofeng Wang, Tong Zheng, Yanwei Cao, Hui Zhang

Abstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Guanyang SongSports Medicine Service, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Daofeng WangSports Medicine Service, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Tong ZhengSports Medicine Service, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Yanwei CaoSports Medicine Service, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Hui ZhangSports Medicine Service, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The diameter of 4-strand semitendinosus and gracilis (ST/G) autograft varies between 6 and 8 mm in most Asian patients. Recent studies showed higher failure rates for ST/G anterior cruciate ligament (ACL) reconstructions (ACLRs) performed with graft diameters <8 mm. The 8-strand ST/G ACL graft preparation technique has been reported to achieve diameters of up to 9.5 to 11.5 mm. Hypotheses: (1) The diameter of the ACL graft would be >8 mm in all cases (100%) by using the 8-strand graft preparation technique and (2) the ACLR with 8-strand ST/G autograft would show satisfactory functional scores, excellent knee stability with good graft signal, and promising graft healing status. Study Design: Case series; Level of evidence, 4. Methods: From January 2020 to January 2022, 67 consecutive patients who underwent primary ACLR with unilateral 8-strand ST/G autograft were prospectively enrolled. Clinical outcomes were assessed using functional scores (Lysholm, Tegner, and International Knee Documentation Committee [IKDC] objective grade) and physical examination results (pivot-shift test and manual maximum KT-1000 side-to-side difference [SSD]). Radiologically, intra-articular ACL graft signal intensity (grade 1, good; grade 2, moderate; grade 3, poor) and anterior subluxation of the lateral compartment (ASLC) and medial compartment (ASMC) in extension relative to the femoral condyles were evaluated on magnetic resonance imaging (MRI) scans. Additionally, second-look arthroscopic evaluations were used to assess the synovial coverage (A, normal [>75%]; B, nearly normal [50%-75%]; C, abnormal [25%-50%]; and D, severely abnormal [<25%]) of the ACL graft. Results: Ultimately, 50 patients were enrolled and completed the minimum 2-year follow-up tasks. The mean graft diameter for the 8-strand graft configuration was 9.3 mm (range, 8.5-10.5 mm). At final follow-up, all of the following showed significant improvements (pre- vs postoperatively): mean Lysholm score (52.7 vs 93.2; Conclusion: The 8-strand graft configuration technique proposed in this study ensured that the diameter of the ST/G ACL autograft reached ≥8 mm. Additionally, this technique demonstrated promising clinical scores, knee stability, and graft maturity in ACLR patients at 2-year minimum follow-up in this cohort.

Indexed as

ACL reconstructionclinical scoregraft configurationgraft maturityradiological outcome

Identifiers

PMID40786917
PMCPMC12334830

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.