Evidence map›Paper›PMID 40785924›Full record

ArticleQuantitative imaging in medicine and surgery2025

Personalized and precise prediction of cage width and implantation angle in transforaminal lumbar interbody fusion: an image analysis of combined application of CT and Surgimap.

Baozhi Ding, Haijun Tian, Jie Zhao, Hui Ma

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Baozhi Ding *Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.ORCID https://orcid.org/0000-0002-0253-4511
Haijun Tian *Department of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.ORCID https://orcid.org/0000-0003-1875-3169
Jie ZhaoShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.ORCID https://orcid.org/0000-0003-1000-5641
Hui MaShanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.ORCID https://orcid.org/0000-0003-2012-7693

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transforaminal lumbar interbody fusion (TLIF) is a commonly used method for treating degenerative diseases of the lumbar spine, but little attention has been paid to the relevant details of its cage. The aim of this study was to investigate and analyze the implantation angle and the maximum selectable width of the cage during TLIF surgery. Methods: A retrospective analysis was conducted on computed tomography (CT) images of patients who underwent single-level TLIF surgery (L4/5) with cages of different widths (50 cases of 10 mm cages and 43 cases of 12 mm cages). Surgimap software was utilized for measurements and the position of the exiting nerve root, the maximum initial angle for cage implantation into the intervertebral space, and the maximum cage width were investigated. Results: During TLIF surgery with pedicle screws and rods in place, the maximum initial implantation angle was 28.56°±4.65° for 10 mm-wide cages and 27.26°±5.34° for 12 mm-wide cages. Theoretically, a cage with a maximum width of 17.56±2.53 mm can be used. The distance from the exiting nerve root to the midline was 19.92±2.62 mm on the left side and 20.85±2.99 mm on the right side. Without the restriction of pedicle screws and rods, the maximum initial implantation angle of the cage was approximately 60°. Conclusions: CT images were analyzed using Surgimap software, revealing that the cage width and implantation angle can be effectively evaluated, facilitating personalized and precise surgical planning.

Indexed as

Cage widthcomputed tomography images (CT images)initial implantation angleSurgimaptransforaminal lumbar interbody fusion (TLIF)