Evidence map›Paper›PMID 40785863›Full record

ArticleQuantitative imaging in medicine and surgery2025

Evaluating the accuracy of the variable flip angle technique for temperature measurement near metallic implants.

Sangwoo Kim, Sukhoon Oh

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Sangwoo KimDepartment of Radiological Science, Daewon University College, Jecheon, Republic of Korea.
Sukhoon OhCenter for Bio-Imaging and Translational Research, Korea Basic Science Institute, Cheongju, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study assessed the accuracy of a T1-based temperature measurement technique for metal-inserted materials using 3T magnetic resonance imaging (MRI). A variable flip angle (VFA) sequence with dual echoes was used to obtain images of a phantom and an

Indexed as

magnetic resonance imaging (MRI)Metal implantT1-based thermometrytemperature mappingvariable flip angle (VFA)

Identifiers

PMID40785863
PMCPMC12332644

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.