Evidence map›Paper›PMID 40785765›Full record

ArticleClinics in orthopedic surgery2025

Optimal Plate Position for Biomechanical Stability in Medial Opening-Wedge High Tibial Osteotomy: A Finite Element Analysis.

Hyun-Soo Moon, Jin-Ho Youn, Sung-Jae Lee, Dae-Kyung Kwak, Kwang-Min Park, Shi-Hyun Kim, Je-Hyun Yoo

Abstract read
In one paragraph

Article in Clinics in orthopedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hyun-Soo MoonDepartment of Orthopedic Surgery, Gangnam Severance Hospital Hospital, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0001-8678-2960
Jin-Ho YounDepartment of Biomedical Engineering, Inje University, Gimhae, Korea.ORCID https://orcid.org/0009-0004-9833-7513
Sung-Jae LeeDepartment of Biomedical Engineering, Inje University, Gimhae, Korea.ORCID https://orcid.org/0000-0001-5511-4839
Dae-Kyung KwakDepartment of Orthopedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Korea.ORCID https://orcid.org/0000-0002-7089-4359
Kwang-Min ParkMedical Device Development Center, Osong Medical Innovation Foundation, Cheongju, Korea.ORCID https://orcid.org/0000-0002-2868-3371
Shi-Hyun KimDepartment of Orthopedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Korea.ORCID https://orcid.org/0009-0008-8971-9367
Je-Hyun YooDepartment of Orthopedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Korea.ORCID https://orcid.org/0000-0002-0777-1575

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Research on the ideal fixation position for plates in medial opening-wedge high tibial osteotomy (MOWHTO) directly applicable in clinical settings is scarce. Therefore, this study aimed to evaluate the biomechanical effects of different plate positions in MOWHTO through finite element analysis (FEA) to explore a potentially optimal plate position. Methods: Utilizing the computed tomography images of a 67-year-old man, a 3-dimensional model of the knee, along with an implant (TomoFix standard plate and screws), was created to simulate a virtual MOWHTO with a 10° medial opening gap. Biomechanical stability analysis of the bone-implant construct was conducted through FEA under physiologic loading simulating a 1-legged stance, with varying plate positions. Configurations for plate fixation, determined by anterior-posterior depth and height, resulted in a total of 9 fixation positions (anterior, center, and posterior in terms of depth; proximal, middle, and distal in terms of height). Criteria for assessment included inter-fragmentary micromotion at the medial opening gap, mean stress on the lateral hinge, the entire tibial bone, and the implant, stress shielding effect, and peak von Mises stress (PVMS). Results: The inter-fragmentary micromotion at the medial opening gap exhibited a tendency to decrease as the fixation position of the plate moved posteriorly and proximally, observed in both axial and shear micromotion. The mean stress on the lateral hinge of the tibia progressively decreased with more posterior or proximal plate placement, reaching its minimum in the most posterior and proximal position. In terms of the mean stress imposed on both the entire bone and implant, it decreased when the plate was positioned posteriorly and proximally, and this position was deemed favorable from the perspective of the stress shielding effect. PVMS predominantly occurred at hole 1 of the plate and its corresponding screw, and it was lower than the yield strength of the titanium alloy regardless of the plate's position. Conclusions: Placing the plate more posteriorly and proximally in MOWHTO could minimize inter-fragmentary micromotion, reduce stress on the lateral hinge and bone-implant construct, and enhance stress shielding, all without increasing the risk of implant breakage, suggesting it as a potentially optimal plate position.

Indexed as

Bone PlatesOsteotomyTibiaAgedBiomechanical PhenomenaFinite Element AnalysisHumansImaging, Three-DimensionalMaleTomography, X-Ray ComputedHigh tibial osteotomyMicromotionPlate positionStabilityStress

Identifiers

PMID40785765
PMCPMC12328103

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.