Evidence map›Paper›PMID 40783565›Full record

ArticleScientific reports2025

Biomechanics of humeral locking plate augmented with fibular strut allograft and intramedullary strut plate using finite element analysis.

Cheng-Hung Lee, Li-Kun Hung, Yu-Chun Yen, Kuo-Chih Su

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Influence of allograft augmentation on surgical outcomes and complications in proximal humerus fractures: a matched-pair analysis.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Cheng-Hung Lee *Department of Orthopedics, Taichung Veterans General Hospital, Taichung, 407, Taiwan.
Li-Kun Hung *Department of Orthopedics, Taichung Veterans General Hospital, Taichung, 407, Taiwan.
Yu-Chun YenDepartment of Medical Research, Taichung Veterans General Hospital, Taichung, 407, Taiwan.
Kuo-Chih SuDepartment of Medical Research, Taichung Veterans General Hospital, Taichung, 407, Taiwan. kcsu@vghtc.gov.tw.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A humeral locking plate augmented with fibular strut allograft treated for proximal humeral fracture without internal structural support is satisfactory. While it is better clinically and biomechanically than the locking plate alone, it has disadvantages, including difficulty to obtain and the possibility of infection. Other alternative augmentation approaches are in demand. Therefore, the hypothesis of this study is whether intramedullary strut plate can replace fibular strut allograft as a surgical method while providing similar biomechanical performance. The finite element analysis (FEA) models were established based on three-dimensional computed tomography images. Computer-aided design implants were incorporated into the models. According to different implants, models were divided into four groups: the intact humerus, humeral locking plate alone (LP), humeral locking plate augmented with fibular strut allograft (FA), and humeral locking plate augmented with intramedullary strut plate (IMP). The displacements and von Mises stresses were measured on the models by simulating axial force, oblique force and torsion. Compared with the LP group, the displacements and von Mises stresses on the humerus and humeral locking plate in the FA, and IMP groups were all smaller in axial force, oblique force, and torsion. The biomechanical effects of FA and IMP in proximal humeral fracture without internal structural support were basically similar in terms of axial force, oblique force, and torsion. Findings provide useful new ideas for implant design. Our FEA simulation indicates that both the fibular strut allograft (FA) and intramedullary strut plate (IMP) offer similar biomechanical stability in treating proximal humeral fractures without internal structural support. This supports the hypothesis that the intramedullary strut plate can effectively replace the fibular strut allograft.

Indexed as

Bone PlatesBone TransplantationFibulaHumerusShoulder FracturesAllograftsBiomechanical PhenomenaFinite Element AnalysisHumansTomography, X-Ray ComputedBiomechanicsFinite element analysisHumeral locking plateProximal humeral fracture

Identifiers

PMID40783565
PMCPMC12335455

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.