Evidence map›Paper›PMID 40783539›Full record

ArticleJournal of cardiothoracic surgery2025

Left ventricular wire pacing technique in transcatheter aortic valve replacement.

Mengnan Shi, Hang Zhang, Jinghui An, Fengwu Shi, Hongning Yin, Suyun Liu

Abstract read
In one paragraph

Article in Journal of cardiothoracic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mengnan ShiDepartment of Cardiology, The Second Hospital of Hebei Medical University, No. 215 of Heping West Road, Xinhua District, Shijiazhuang, 050000, China.
Hang ZhangDepartment of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, China.
Jinghui AnDepartment of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, China.
Fengwu ShiDepartment of Cardiac Surgery, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, China.
Hongning YinDepartment of Echocardiography, The Second Hospital of Hebei Medical University, Shijiazhuang, 050000, China.
Suyun LiuDepartment of Cardiology, The Second Hospital of Hebei Medical University, No. 215 of Heping West Road, Xinhua District, Shijiazhuang, 050000, China. suyunliulsy@126.com.

Funding

The government funded the clinical medicine outstanding talent training project 2020397
6 · The paper itself

Abstract

objectiveTo assess the impact of using the left ventricular lead pacing technique in transcatheter aortic valve replacement (TAVR) procedure.

methodsThirty patients who underwent TAVR using the left ventricular lead pacing technique between January 2022 and July 2022 were selected as the study group. The research monitored intraoperative pacing effectiveness, the successful placement of "valve-in-valve" during the surgical procedure, the frequency of severe complications both during and after the surgery, surgical duration, total radiation dose, and overall hospitalization expenses. Additionally, the occurrence of adverse events such as mortality, stroke, and myocardial infarction within the three-month period subsequent to the surgery was documented.

resultsAll patients underwent successful pacing and completed TAVR with left ventricular lead pacing, with 29 cases conducted through the transfemoral approach and 1 case through the transcarotid approach. A total of 32 interventional valves were effectively implanted, including 2 cases of "valve-in-valve" treatment. Intraoperative circulatory collapse occurred in 2 cases but was promptly managed and resolved. Mild paravalvular leak was observed in 25 cases post-surgery, while no significant paravalvular leaks were detected in the remaining cases. None of the patients experienced III-degree atrioventricular block or other cardiac conduction blocks necessitating temporary or permanent pacemaker implantation post-surgery. Preoperative symptoms were alleviated or completely resolved to varying extents. The average surgery duration was 86.8 ± 18.2 min, total radiation dose was 756.5 ± 131 mGy, and total hospitalization costs were 33.18 ± 2.5 ten thousand yuan (5.10 ± 0.38 ten thousand US dollars). During the three-month postoperative follow-up, no adverse events such as fatality, stroke, or myocardial infarction were reported.

conclusionThe use of the left ventricular lead pacing technique in TAVR demonstrates both safety and reliability.

Indexed as

Aortic Valve StenosisCardiac Pacing, ArtificialHeart VentriclesTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleHumansMalePostoperative ComplicationsRetrospective StudiesTreatment OutcomeArtificialCardiac PacingHeart Valve Prosthesis ImplantationTranscatheter Aortic Valve Replacement Aortic Valve Stenosis

Identifiers

PMID40783539
PMCPMC12335046

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.