ArticleJapanese journal of radiology2025
Low-tube-potential ultra-high-resolution coronary CTA with photon-counting detector CT for stent evaluation: a comparative feasibility study.
Article in Japanese journal of radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Propensity score matching and clinical interpretation-comment on Araki et al.Japanese journal of radiology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThis study aimed to evaluate the feasibility of low-tube-potential ultra-high-resolution (UHR) coronary CT angiography (CCTA) using photon-counting detector CT (PCD-CT) in comparison to low-tube-potential CCTA using energy-integrating detector CT (EID-CT), with a specific focus on the evaluation of coronary stents. MATERIALS AND
methodsThis retrospective study included 54 patients (88 stents) who underwent CCTA in UHR mode on PCD-CT at low tube potential (PCD
resultsPCD
conclusionCCTA using UHR mode in PCD-CT at low tube potential achieved superior image quality for implanted stent visualization as compared to EID-CT at low tube potential, while maintaining comparable radiation doses.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.