Biomechanical evaluation of bispherical augments in acetabular defect reconstruction and comparative study of different fixation methods.

Xiaoqi Zhang, Guoyuan Li, Min Chen, Zhe Ni, Zhengliang Luo, Xiaofeng Ji, Xifu Shang

Abstract readComparative Study
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiaoqi ZhangCheeloo College of Medicine, Shandong University, Jinan, 250012, Shandong, China.ORCID http://orcid.org/0000-0001-9763-1068
Guoyuan LiDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, Anhui, China.ORCID https://orcid.org/0000-0002-4480-3388
Min ChenDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, Anhui, China.ORCID https://orcid.org/0009-0000-2505-4142
Zhe NiDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, Anhui, China.
Zhengliang LuoDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, Anhui, China.ORCID https://orcid.org/0009-0009-1284-9910
Xiaofeng JiDepartment of Orthopedics, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, Anhui, China.
Xifu ShangCheeloo College of Medicine, Shandong University, Jinan, 250012, Shandong, China. shangxifuchina@163.com.ORCID https://orcid.org/0000-0002-9247-0549

Funding

Hefei Comprehensive National Science Center 2023IHM01075the Joint Fund for Medical Artificial Intelligence MAI2023Q027the National Natural Science Foundation of China 82072408the Natural Science Foundation of Anhui Province 2308085MH251
6 · The paper itself

Abstract

backgroundNovel bispherical augments developed for acetabular defect reconstruction, which combined with acetabular components, have shown excellent results in clinical follow-up. This study aims to evaluate the primary stability of them in severe acetabular defect reconstruction and biomechanical effect using different combine methods in the component-augment interface, and to further explain their value in clinical applications.

methodsNine composite hemipelvis specimens were prepared with a Paprosky II defect. A porous titanium acetabular shell and bispherical augment were combined and implanted for acetabular defect reconstruction. The augment was fixed to the hemipelvis using screws, while three specimens per groups of three groups were varied by different fixation techniques between the augments and acetabular components: (1) screw fixation only, (2) cement fixation only, and (3) screw and cement fixation. The combined components and hemi pelvic specimens were cyclically loaded (500 cycles) with three different levels of loads (maximum 0.5 kN, 0.9 kN, and 1.8 kN).

resultsAll constructs had micromotions of less than 99 μm, and bony ingrowth could be achieved between the prostheses and the bone in 3-30% and 5-50% loads. The cement groups showed the maximum relative movement in the interface between the bone and combined prosthesis, especially when the load was increased to 1.8 kN (100%), while in which the hybrid groups had the minimum value.

conclusionThe study indicates that acetabular defect reconstruction utilizing the bispherical augments can achieve excellent primary stability, which provides the mechanical condition of bone ingrowth for prostheses and augments. The hybrid fixation is the most reliable of them, even under full loads.

Indexed as

AcetabulumArthroplasty, Replacement, HipHip ProsthesisPlastic Surgery ProceduresBiomechanical PhenomenaBone CementsBone ScrewsHumansProsthesis DesignTitaniumBone CementsTitaniumAcetabular revisionBispherical augmentsPrimary stabilityTotal hip revision

Identifiers

PMID40775325
PMCPMC12330107

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.