Evidence map›Paper›PMID 40773500›Full record

ArticlePloS one2025

Robust skeletal motion tracking using temporal and spatial synchronization of two video streams.

Vytautas Abromavičius, Ervinas Gisleris, Kristina Daunoravičienė, Jurgita Žižienė, Artūras Serackis, Rytis Maskeliūnas

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Vytautas AbromavičiusFaculty of Informatics, Kaunas University of Technology, Kaunas, Lithuania.ORCID https://orcid.org/0000-0003-1588-6572
Ervinas GislerisDepartment of Electronic Systems, Vilnius Gediminas Technical University, Vilnius, Lithuania.ORCID https://orcid.org/0009-0004-6382-9016
Kristina DaunoravičienėDepartment of Biomechanical Engineering, Vilnius Gediminas Technical University, Vilnius, Lithuania.
Jurgita ŽižienėDepartment of Biomechanical Engineering, Vilnius Gediminas Technical University, Vilnius, Lithuania.
Artūras SerackisDepartment of Electronic Systems, Vilnius Gediminas Technical University, Vilnius, Lithuania.
Rytis MaskeliūnasFaculty of Informatics, Kaunas University of Technology, Kaunas, Lithuania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate and reliable skeletal motion tracking is essential for rehabilitation monitoring, enabling objective assessment of patient progress and facilitating telerehabilitation applications. Traditional marker-based motion capture systems, while highly accurate, are costly and impractical for home rehabilitation, whereas marker-less methods often suffer from depth estimation errors and occlusions. Recent studies have explored various computer vision and deep learning approaches for human pose estimation, yet challenges remain in ensuring robust depth accuracy and tracking under occlusion conditions. This study proposes a three-dimensional human skeleton tracking system for upper limb activities that integrates temporal and spatial synchronization to improve depth estimation accuracy for rehabilitation exercises. The proposed system combines a 90° secondary camera to compensate for the depth prediction inaccuracies inherent in single-camera systems, reducing error margins by up to 0.4 m. In addition, a linear regression-based depth error correction model is implemented to refine depth coordinates, further improving tracking precision. The Kalman filtering framework is employed to enhance temporal consistency, allowing real-time interpolation of missing joint positions. Experimental results demonstrate that the proposed method significantly reduces depth estimation errors of the elbow and wrist joint (p < 0.001) compared to single camera setups, particularly in scenarios involving occlusions and non-frontal perspectives. This study provides a cost-effective and scalable solution for remote patient monitoring and motor function evaluation.

Indexed as

Video RecordingAlgorithmsElbow JointHumansMovementWrist Joint

Identifiers

PMID40773500
PMCPMC12331063

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.