ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2025
A Fully Populated Transrectal Array for Boiling Histotripsy Ablation of the Prostate.
Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it.
- High-Intensity Focused Ultrasound Versus Robot-Assisted Radical Prostatectomy for Localized Prostate Cancer: A Systematic Review and Meta-Analysis of Oncologic and Functional Outcomes.Annals of surgical oncology · 2026Pooled it
- Aberration correction expands the treatment envelope for histotripsy in the liver.Physics in medicine and biology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
The endorectal ultrasound (US)-guided thermal ablation of prostate cancer (PCa) using high-intensity focused ultrasound (HIFU) is a widely used focal intervention. While generally safe and effective, it is not without challenges associated with heat diffusion and prefocal heating, which has spurred interest toward nonthermal and mechanical HIFU ablation regimes. Another challenge is the necessity to mechanically translate the HIFU transducer-commonly single-element or annular array-for volumetric treatments, which results in target shifts and transducer position readjustment. The 2-D arrays would address this problem, but their design is challenging in a small form factor. The element pattern must be tightly packed and aperiodic to maximize the active surface area and to suppress grating lobes, respectively. Here, we report on the design, fabrication, and performance evaluation of a 1.5-MHz 128-element transrectal HIFU array driven by Verasonics system capable of mechanical tissue ablation via boiling histotripsy (BH) under real-time coaxial US imaging guidance. A recently developed method for designing randomized, fully populated mosaic arrays was used to create the element pattern. The measured focus steering ranges of the fabricated array were 26 mm axially and 12 mm laterally in the BH regime, with driving voltage compensation by less than 43% and no grating lobe formation. Stress tests with a five-element prototype confirmed safe operating voltage of 850-V peak-to-peak, corresponding to the acoustic intensity of 542 W/cm2 at the array surface. The array integrated with a 128-element US imaging probe driven by the same Verasonics system was successfully used to produce volumetric BH lesions in polyacrylamide (PAA) tissue-mimicking phantoms.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.