Evidence map›Paper›PMID 40764980›Full record

ArticleBMC medical imaging2025

Determination of redundant scan coverages along the Z-axis and dose implications for common paediatric computed tomography imaging examinations in a limited resource setting.

Rosemary Yeboah Ampofo, Kofi Adesi Kyei, Joseph Daniels, Andrew Yaw Nyantakyi

Abstract read
In one paragraph

Article in BMC medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Microvascular Imaging of Hepatic Hemangiomas.Diagnostics (Basel, Switzerland) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Rosemary Yeboah AmpofoDepartment of Radiography, University of Ghana, P.O.Box 143, Legon, Accra, Ghana.
Kofi Adesi KyeiDepartment of Radiography, University of Ghana, P.O.Box 143, Legon, Accra, Ghana. kakyei@ug.edu.gh.
Joseph DanielsNational Centre for Radiotherapy, Oncology and Nuclear Medicine, Korle-Bu Teaching Hospital, P.O. Box KB 369, Accra, Ghana.
Andrew Yaw NyantakyiNational Centre for Radiotherapy, Oncology and Nuclear Medicine, Korle-Bu Teaching Hospital, P.O. Box KB 369, Accra, Ghana.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOptimizing scan parameters, particularly along the Z-axis, is crucial for minimizing unnecessary medical radiation exposure. Understanding and mitigating redundant scan coverages is essential for enhancing the safety and efficacy of paediatric CT imaging. This study quantified redundant Z-axis scan coverage and evaluated its associated dose implications in paediatric CT examinations in a limited-resource healthcare setting.

methodsA retrospective review was conducted on 279 paediatric CT scan records from two large tertiary hospitals in Ghana. Distances above the upper target and below the lower target of selected anatomical regions were measured using calibrated callipers on the CT console. The National Cancer Institute Dosimetry System for Computed Tomography (Monte Carlo-based software) was used to simulate the scanning situations and organ-dose implications.

resultsIn all, 87.3% of the CT scans had redundancies ranging from 0.77 ± 0.42 to 2.34 ± 1.22 cm for head, 1.43 ± 2.36 to 5.64 ± 3.00 cm for chest and 4.86 ± 3.01 to 6.75 ± 4.28 cm for abdominopelvic CT scans. Optimizing the scan length to the appropriate anatomical boundaries reduced the total dose-length product of neonates and middle-aged children by 27.9% and 26.1% respectively for chest CT scans, and 26.2% for infants during abdominopelvic CT scans. Optimal scan length selection for chest CT examinations resulted in organ-dose reductions of 57.5%, 56.1%, 63.6% and 73.8% for the thyroid glands, heart wall, lungs and breasts respectively.

conclusionThe study demonstrates a high prevalence (87.3%) of redundant scan coverage in paediatric CT examinations, with significant variances across different body sites. Implementing optimized scan lengths could substantially reduce radiation exposure and significantly lower organ doses.

Indexed as

Radiation DosageTomography, X-Ray ComputedAdolescentChildChild, PreschoolFemaleGhanaHumansInfantInfant, NewbornMaleRetrospective StudiesPaediatric computed tomographyPaediatric imagingRadiation doseRedundant scan coveragesScan length

Identifiers

PMID40764980
PMCPMC12326660

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.