Evidence map›Paper›PMID 40764360›Full record

ArticleScientific reports2025

Enhancing the performance of grid-connected DFIG systems using prescribed convergence law.

Hichem Itouchene, Fayssal Amrane, Zoubir Boudries, Saad Mekhilef, Habib Benbouhenni, Nicu Bizon

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hichem ItoucheneFaculté de Technologie, Laboratoire de Technologie Industrielle et de l'Information (LTII), Université de Bejaia, Bejaia, 06000, Algérie.
Fayssal AmraneLAS Research Laboratory, LEPCI Research Laboratory, Department of Electrotechnics, Faculty of Technology, Setif-1 University Ferhat ABBAS, Setif, 19000, Algeria. amrane_fayssal@univ-setif.dz.
Zoubir BoudriesFaculté de Technologie, Laboratoire de Technologie Industrielle et de l'Information (LTII), Université de Bejaia, Bejaia, 06000, Algérie.
Saad MekhilefSchool of Engineering, Swinburne University of Technology, Hawthorn, VIC, 3122, Australia.
Habib BenbouhenniEcole Nationale Polytechnique d'Oran, Laboratoire LAAS, EL M'naouer, Bp 1523, Oran, Algeria.
Nicu BizonThe National University of Science and Technology POLITEHNICA Bucharest, Pitești University Centre, Pitesti, 110040, Romania. nicu.bizon1402@upb.ro.

Funding

The National University of Science and Technology POLITEHNICA Bucharest 313 Splaiul Independenței Street, sector 6, Bucharest, Romania PN-IV-P7-7.1-PED-2024-0567
6 · The paper itself

Abstract

In this paper, a robust and effective control strategy, termed high-order prescribed convergence law control (HO-PCL), is introduced for wind energy conversion systems. This innovative strategy is applied to the rotor-side converter of a doubly-fed induction generator-based wind power system and is specifically designed to address the limitations of conventional control methods, such as super-twisting algorithm (STA), integral backstepping control (IBCS), and first-order sliding mode control (1-SMC), which are prone to the chattering phenomenon. The HO-PCL strategy facilitates the independent regulation of active and reactive power, with the primary objective of enhancing the system's dynamic response by improving response time and minimizing power error. The effectiveness of the proposed control approach is evaluated through simulations conducted in the MATLAB/Simulink environment and validated via hardware-in-the-loop (HIL) testing under different operating conditions, where the performance and effectiveness are compared with that of the conventional proportional-integral (PI) controller, 1-SMC, and IBCS approaches. Simulation results show that the proposed HO-PCL approach reduces the stator current total harmonic distortion by 94.01, 91.05, and 85% compared to the PI, 1-SMC, and IBCS approaches, respectively. Additionally, it reduces response time by 99.25, 98.96, 93% relative to the same respective methods. Furthermore, the HO-PCL approach significantly improves the ripple and overshoot of power compared to other strategies. The results demonstrate its potential to advance control methodologies in wind power systems by overcoming the drawbacks of conventional techniques.

Indexed as

Doubly-fed induction generatorsHardware-in-the-loopHigh-order prescribed convergence law controlSliding mode controlTotal harmonic distortionWind energy conversion system

Identifiers

PMID40764360
PMCPMC12325639

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.