Evidence map›Paper›PMID 40762992›Full record

ArticleRevista da Escola de Enfermagem da U S P2025

Clinical validation of the diagnosis adverse location of peripherally inserted central catheter in neonatology.

Nanete Caroline da Costa Prado, Richardson Augusto Rosendo da Silva, Harlon França de Menezes, Isabele Silva Dos Santos, Rebecca Stefany da Costa Santos, Sérgio Danillo Santana de Lima Juraci, Dhyanine Morais de Lima Raimundo, Romanniny Hévillyn Silva Costa Almino

Abstract readValidation Study
In one paragraph

Article in Revista da Escola de Enfermagem da U S P, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Developing a Subset of ICNPHealthcare (Basel, Switzerland) · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nanete Caroline da Costa PradoUniversidade Federal do Rio Grande do Norte, Programa de Pós-graduação em Enfermagem, Natal, RN, Brazil.ORCID 0000-0002-9079-0450
Richardson Augusto Rosendo da SilvaUniversidade Federal do Rio Grande do Norte, Programa de Pós-graduação em Enfermagem, Natal, RN, Brazil.ORCID 0000-0001-6290-9365
Harlon França de MenezesUniversidade Federal do Rio Grande do Norte, Programa de Pós-graduação em Enfermagem, Natal, RN, Brazil.ORCID 0000-0001-9884-6511
Isabele Silva Dos SantosUniversidade Federal do Rio Grande do Norte, Programa de Pós-graduação em Enfermagem, Natal, RN, Brazil.ORCID 0000-0003-0735-4904
Rebecca Stefany da Costa SantosUniversidade Federal do Rio Grande do Norte, Programa de Pós-graduação em Enfermagem, Natal, RN, Brazil.ORCID 0000-0002-1191-0232
Sérgio Danillo Santana de Lima JuraciUniversidade Federal do Rio Grande do Norte, Programa de Pós-graduação em Enfermagem, Natal, RN, Brazil.ORCID 0009-0005-2857-5804
Dhyanine Morais de Lima RaimundoUniversidade Federal do Rio Grande do Norte, Programa de Pós-graduação em Enfermagem, Natal, RN, Brazil.ORCID 0000-0002-9723-705X
Romanniny Hévillyn Silva Costa AlminoUniversidade Federal do Rio Grande do Norte, Programa de Pós-graduação em Enfermagem, Natal, RN, Brazil.ORCID 0000-0001-7159-0157

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo determine the accuracy measures of clinical indicators of Nursing Diagnosis (ND) of the International Classification of Nursing Practice (ICNP)®, Adverse Location of Peripherally Inserted Central Catheter in a Neonatal Intensive Care Unit (NICU).

methodsDiagnostic accuracy study carried out with 40 neonates admitted to a NICU in Northeastern Brazil. Data collection was performed through clinical examination and application of an institutional instrument. The clinical indicators analysis of the respective ND was performed using accuracy measures.

resultsAmong the study participants, the majority were female and had low birth weight. The prevalence of ND was 57.5%. The clinical indicators 'difficulty in catheter progression' and 'absence of blood return' showed high specificity values. The catheter insertion site, prematurity, and the occurrence of adverse events presented higher sensitivity values.

conclusionAccurate diagnostic inference allows the early identification of inadequate catheter tip positioning, supporting nurses in developing precise and effective interventions to avoid complications.

Indexed as

Catheterization, Central VenousCatheterization, PeripheralNursing DiagnosisBrazilFemaleHumansInfant, NewbornIntensive Care Units, NeonatalMale

Identifiers

PMID40762992
PMCPMC12330225

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.