ArticleRadiology case reports2025
Penetration of inferior vena cava (IVC) filter into abdominal aorta and repairing by Dacron patch arthroplasty: A case report.
Article in Radiology case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Aortic pseudoaneurysm caused by Tempofilter II inferior vena cava filter strut perforation: a case report.Frontiers in surgery · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Inferior vena cava (IVC) filters are ordinarily used to prevent pulmonary embolism (PE) in patients with contraindications to anticoagulation or those with an experience of bleeding after anticoagulation therapy. We present a 54-year-old female with a complex medical history, including diabetes mellitus, who developed acute deep vein thrombosis (DVT) after right common femoral vein (RCFV) catheter insertion, necessitating intravenous Heparin therapy. Anticoagulation was discontinued due to gastrointestinal bleeding, prompting inferior vena cava (IVC) filter insertion. Prolonged dwell time led to filter penetration into the abdominal aorta with partial thrombosis, identified on imaging before planned retrieval. The patient underwent open surgery with filter removal and aortic repair using a Dacron patch. This case emphasizes the role of regular follow-up imaging and timely intervention in preventing life-threatening complications of filter retention.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.