Evidence map›Paper›PMID 40760268›Full record

ArticleJournal of medical toxicology : official journal of the American College of Medical Toxicology2025

Smartwatch Detection of Refractory Hypoxemia in Phenazopyridine-Induced Methemoglobinemia: A Case Report.

Leann N Tulisiak, Mackenzie E Loesing, Alexander Ljungberg, Eric E Kaczor

Abstract readCase Reports
In one paragraph

Article in Journal of medical toxicology : official journal of the American College of Medical Toxicology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Leann N TulisiakDepartment of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
Mackenzie E LoesingDepartment of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
Alexander LjungbergDepartment of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
Eric E KaczorDepartment of Emergency Medicine, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA. erickacz428@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionSignificant cases of methemoglobinemia will cause a signal interference in traditional dual-wavelength pulse oximetry leading to the classic finding of “refractory hypoxemia”. As smartwatches begin to incorporate pulse oximetry capabilities, it is unclear whether these devices will demonstrate the same type of interference in the presence of methemoglobinemia. This article reports a case where a patient’s Apple Watch© reported a hypoxemia alert in the setting of phenazopyridine induce methemoglobinemia. CASE REPORT: This is a case report of a 71-year-old female whose Apple Watch© reported a hypoxemia alarm in the setting of methemoglobinemia caused by phenazopyridine use. The patient’s smartwatch began signaling hypoxemia alerts the day before she noticed clinical cyanosis. 24 hours after the hypoxemia alerts began, she presented to the Emergency Department (ED) with shortness of breath and blue discoloration of skin. The Apple Watch© recorded oxygen saturation readings between 73% and 86%. Upon arrival to the ED, the patient’s SpO2 was 84% on traditional hospital-grade dual-wavelength pulse oximetry and her methemoglobin level was 19.8%. Her symptoms and methemoglobinemia resolved after administration of 1 mg/kg of IV methylene blue.

conclusionPulse oximetry used in smartwatch technology can trigger a hypoxemia alarm in the presence of drug-induced methemoglobinemia. If demonstrated to be a reproducible finding, smartwatch technology has the potential to be used as part of an early detection system for clinically significant methemoglobinemia.

Indexed as

Clinical AlarmsHypoxiaMethemoglobinemiaOximetryPhenazopyridineAgedFemaleHumansOxygen SaturationPredictive Value of TestsPhenazopyridineBiosensorsMethemoglobinemiaPhenazopyridinePulse OximetryWearable Electronic Devices

Identifiers

PMID40760268
PMCPMC12511463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.