Evidence map›Paper›PMID 40754891›Full record

ArticleJournal of neuroimaging : official journal of the American Society of Neuroimaging

Optic Nerve Sheath Diameter: Which Axis Should Be Measured?

Jakob Pansell, Tina Thomsson, Emelie Eng, Andreas Wallin, Mohammad Hirzallah

Abstract read
In one paragraph

Article in Journal of neuroimaging : official journal of the American Society of Neuroimaging. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. 3D Imaging and Measurement of Optic Nerve Sheath Diameter.Translational vision science & technology · 2026
    Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jakob PansellThe Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.ORCID https://orcid.org/0000-0002-6665-0589
Tina ThomssonThe Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
Emelie EngThe Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
Andreas WallinThe Department of Neurobiology, Care Sciences and Society, Division of Physiotherapy, Karolinska Institutet, Huddinge, Sweden.
Mohammad HirzallahDepartments of Neurology and Neurosurgery, Baylor College of Medicine, Houston, Texas, USA.

Funding

Stockholm Region Innovations Fund
6 · The paper itself

Abstract

background and purposeOptic nerve sheath diameter (ONSD) measured by point-of-care ultrasound (POCUS) is a commonly used non-invasive estimate of intracranial pressure (ICP). However, methodological variations limit standardization of this promising technique. Different imaging axes are identified as one such source of ONSD POCUS methodological variation. This study aimed to evaluate the agreement and diagnostic accuracy for elevated ICP between transverse and sagittal ONSD measurements.

methodsWe conducted a post-hoc analysis of 213 intensive care patients from three prior studies. ONSD was measured in both transverse and sagittal planes, externally (ONSDext) and internally (ONSDint) of the dura mater. Agreement was assessed using Lin's concordance correlation coefficient (CCC). Diagnostic accuracy for detecting ICP ≥20 mmHg was evaluated using area under the receiver operator characteristics curve (AUROC) analyses in a subset of 139 patients.

resultsSagittal ONSD was significantly larger than transverse ONSD (median difference 0.2 mm, p<0.001). Agreement between transverse and sagittal ONSD was poor (CCC: 0.65 and 0.70 for right and left side ONSDext, and 0.43 and 0.51 for right and left side ONSDint). No significant differences in AUROC were found between transverse, sagittal, or averaged measurements.

conclusionsTransverse and sagittal ONSD measurements are not interchangeable due to significant differences and poor agreement. Diagnostic accuracy was similar across methods. These findings support continued use of transverse measurement as the standard approach for ONSD POCUS in clinical practice.

Indexed as

Intracranial HypertensionOptic NerveAdultAgedFemaleHumansIntracranial PressureMaleMiddle AgedPoint-of-Care SystemsReproducibility of ResultsUltrasonographycerebral edemacritical careintensive careintracranial pressureoptic nerve sheath diametersonographyultrasound

Identifiers

PMID40754891
PMCPMC12319288

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.