Evidence map›Paper›PMID 40753234›Full record

ArticleBMC musculoskeletal disorders2025

The influence of proximal femur CT value on stress distribution and stability in intertrochanteric fracture after PFNA fixation: a finite element analysis.

Kaifeng Ye, Yongqiang Wang, Yanlei Dong, Yuanyu Hu, Yutian Luo, Junbo Qi, Yun Tian

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kaifeng Ye *Department of Orthopedics, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191, China.
Yongqiang Wang *Department of Orthopedics, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191, China.
Yanlei Dong *Department of Orthopedics, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191, China.
Yuanyu HuDepartment of Orthopedics, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191, China.
Yutian LuoDepartment of Orthopedics, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191, China.
Junbo QiDepartment of Orthopedics, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191, China.
Yun TianDepartment of Orthopedics, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191, China. tiany@bjmu.edu.cn.

Funding

Peking University Third Hospital,China LM2022775
6 · The paper itself

Abstract

purposeThis study was conducted to develop a finite element analysis (FEA) model for proximal femoral nail antirotation (PFNA) fixation for intertrochanteric femoral fractures, aiming to analyze the effects of varying proximal femur trabecular bone CT values on stress distribution and device stability, as well as to determine their relationships.

methodsWe established a three-dimensional model for PFNA fixation of intertrochanteric femoral fractures based on computed tomography images. Different elastic moduli were assigned to the trabecular bone according to varying proximal femur CT values, enabling an analysis of the differences in stress distribution and maximum displacement of the model under the same loading conditions.

resultsUnder the same stress loading conditions, as the CT values of the proximal femoral trabecular bone decreased from 160 to 120, 80, 40, and 0 HU, the von Mises stress values around the trabecular bone decreased. Moreover, the stress values near the cortical bone, intramedullary nail, screw tip, and junction between the screws and the main nail increased. Additionally, the maximum displacement of the entire model also increased. This finding indicates that as the proximal femur CT values decreased, the load on the cortical bone and internal fixation increased, leading to greater instability of the model and a higher risk of internal fixation failure.

conclusionAs the CT value of the proximal femoral trabecular bone decreases, the stability of the PFNA fixation device diminishes, leading to increased stress on both the cortical bone and the intramedullary nail, thereby increasing the risk of PFNA fixation failure.

Indexed as

FemurFinite Element AnalysisFracture Fixation, IntramedullaryHip FracturesTomography, X-Ray ComputedBiomechanical PhenomenaBone NailsHumansImaging, Three-DimensionalProximal Femoral FracturesStress, MechanicalCT valueFinite element analysisIntertrochanteric fractureProximal femoral nail antirotation (PFNA)

Identifiers

PMID40753234
PMCPMC12317588

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.