Evidence map›Paper›PMID 40747424›Full record

ArticlebioRxiv : the preprint server for biology2025

Robust-tedana: An automated denoising pipeline for multi-echo fMRI data.

Bahman Tahayori, Robert E Smith, David N Vaughan, Chris Tailby, Daniel A Handwerker, Eric Y Pierre, Graeme D Jackson, David F Abbott

Abstract readPreprint
In one paragraph

Article in bioRxiv : the preprint server for biology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Bahman TahayoriThe Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia.ORCID 0000-0002-4927-0023
Robert E SmithThe Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia.ORCID 0000-0003-3636-4642
David N VaughanThe Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia.ORCID 0000-0002-6225-7739
Chris TailbyThe Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia.
Daniel A HandwerkerIntramural Research Program, National Institute of Mental Health, Bethesda, MD, USA.ORCID 0000-0001-7261-4042
Eric Y PierreThe Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia.ORCID 0000-0002-3196-5417
Graeme D JacksonThe Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia.ORCID 0000-0002-7917-5326
David F AbbottThe Florey Institute of Neuroscience and Mental Health, Heidelberg, Victoria, Australia.ORCID 0000-0002-7259-8238

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Multi-echo functional Magnetic Resonance Imaging (fMRI) data are acquired by recording image volumes at multiple echo times and can be used to improve the separation of neural activity from noise. TE-Dependent ANAlysis (tedana) is an open-source software tailored to denoising of multi-echo fMRI data. The efficacy of denoising can however be inconsistent, often necessitating manual inspection that precludes its application in large-scale studies where processing is ideally fully automated. Here, we introduce Robust-tedana, an optimised denoising pipeline that achieves adequate results at both single-subject and group level. Robust-tedana incorporates Marchenko-Pastur Principal Component Analysis (MPPCA) for effective thermal noise reduction, robust independent component analysis for stabilised signal decomposition, and a modified component classification process. We evaluated its performance on Multi-Band Multi-Echo (MBME) language-task fMRI data from the Australian Epilepsy Project (AEP) using objective measures, comparing to conventional fMRI analysis with and without multi-echo-based denoising. Experts' manual evaluation was undertaken on a subset of these data to validate the objective measures. The proposed pipeline both mitigates the prevalence of erroneous attenuation of genuine task activation due to instability of single-subject analysis, and increases the magnitude of group-wise effects. Robust-tedana therefore facilitates advanced analysis of MBME fMRI data in an automated pipeline, including for clinical research assessment of individuals.

Indexed as

DenoisingLanguage taskMulti-echo fMRI Robust independent component analysis

Identifiers

PMID40747424
PMCPMC12312181

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.