Evidence map›Paper›PMID 40746390›Full record

ArticleApplied magnetic resonance2025

Comparison of 10 mm and 30 mm Diameter Surface Coil Resonators for 1 GHz EPR.

Georgina Amassah, Tanden A Hovey, George A Rinard, Sandra S Eaton, Gareth R Eaton

Abstract read
In one paragraph

Article in Applied magnetic resonance, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Georgina AmassahDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210 USA.
Tanden A HoveyDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210 USA.
George A RinardRitchie School of Engineering and Computer Science, University of Denver, Denver, CO 80210 USA.
Sandra S EatonDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210 USA.
Gareth R EatonDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80210 USA.

Funding

Preclinical Electron Paramagnetic Resonance Tumor ImagerR01CA262159 · NCI · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2021 to 2025
$2.6M
NCI NIH HHS R01 CA262159
6 · The paper itself

Abstract

Two surface coil resonators were tested at 1.0 GHz as alternatives to volume resonators that fully contain the sample; a 10 mm diameter coil with Q of 61 and efficiency of 0.044 mT/√W at ~2.5 mm above the coil and a 30 mm diameter coil with Q of 56 and efficiency of 0.0038 mT/√W at ~5 mm above the coil. The 10 mm diameter coil uses power more efficiently, but the 30 mm diameter surface coil detects signal from a larger volume and the B

Identifiers

PMID40746390
PMCPMC12308331

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.