Evidence map›Paper›PMID 40746373›Full record

ArticleMedical journal of the Islamic Republic of Iran2025

Dual Mobility Acetabular Cup Utilization in Total Hip Arthroplasty: Mitigating Instability Risks.

Javad Khaje Mozafari, Amir Aminian, Ali Yeganeh, Mansour Abolghasemian

Abstract read
In one paragraph

Article in Medical journal of the Islamic Republic of Iran, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Javad Khaje MozafariBone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Amir AminianBone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Ali YeganehBone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.ORCID https://orcid.org/0000-0002-9015-1763
Mansour AbolghasemianDivision of Orthopedic Surgery, Department of Surgery, Faculty of Dentistry and Medicine, University of Alberta, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: With the increase in life expectancy and the rising number of total hip arthroplasty (THA) cases, the rate of complications is also expected to increase. One of the most challenging complications is dislocation, which is the leading cause of revision surgery within the first year after THA. This study aimed to assess hip instability rates in high-risk patients who underwent dual mobility cup (DMC) implantation. Methods: This retrospective study reviewed all patients who underwent THA with DMC at Rasul-e-Akram Hospital between 2014 and 2021. DMC was used in high-risk patients for dislocation, including those with neuromuscular diseases (e.g., Parkinson's disease, poliomyelitis) and intracapsular femoral neck fractures (FNF), instead of the standard cup. Clinical outcomes, instability, and other complications were recorded. All data was analyzed using SPSS software version 27.0.1. The chi-squared test was used to compare binary variables, and the student's t-test was used to compare numerical variables after checking for normal distribution. Results: A total of 163 patients (168 hips) underwent THA with DMC, with a mean age of 58 ± 5.3 years. Five patients had bilateral total hip surgery. The average follow-up time was 48 ± 5.8 months. The average BMI of patients was 28.3 ± 3.1. The preoperative Harris Hip Score (HHS) was 49 ± 8.5, while the postoperative HHS at the four-year follow-up was 89 ± 2.4. None of the patients experienced a dislocation requiring revision, and One case of severe wear on the polyethylene's inner surface and intraprosthetic dislocation, without a dislocated metal head, was identified and revised. No cases of component loosening or significant osteolysis were observed. Conclusion: The use of DMC can significantly reduce the dislocation rate in patients with risk factors such as femoral neck fractures while improving patient satisfaction and restoring near-normal function. We recommend greater consideration of this cup in patients at risk of dislocation.

Indexed as

Dual Mobility Cupfemur neck fractureOsteonecrosisRisk factor of DislocationTotal Hip Arthroplasty

Identifiers

PMID40746373
PMCPMC12313306

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.